2.1 Operating modes
TopVent
®
GV operates in the following modes:
■
Off
■
Recirculation
■
Recirculation night
TempTronic regulates these modes of operation automatically.
Code
Operating mode
Description
OFF
Off
The fan is switched off. Frost protection for the room remains active. There is no
room temperature control.
Fan ..............................off
Heating ........................off
REC
Recirculation
On/off-operation: if heating is required, the unit draws in room air, heats it and
returns the warm air back into the room. The room temperature set value day is
active.
Fan ..............................modulated
1)
Heater ..........................modulated
1)
1)
Depending on heat demand
RECN
Recirculation night
like REC, but with room temperature set value night
Table D1: TopVent
®
GV operating modes
■
1
Access panel
■
2
Burner control
■
3
Burner unit consisting of stainless steel
gas blower and premix burner
■
4
Gas control valve
■
5
Terminal strip
■
6
Combustion air connection
■
7
Flue gas connection
■
8
Gas connection
■
9
Fan
■
10
Casing
■
11
Heat exchanger of stainless steel
■
12
Air outlet louvre
Fig. D1: TopVent
®
GV structure
D
35
TopVent
®
GV
Construction and operation
Use
Содержание DGV-6/30
Страница 2: ......
Страница 4: ...2...
Страница 5: ...Safety A 1 Symbols 4 2 Operational safety 4 3 Information for a user manual 4 3 Safety Content...
Страница 20: ...18...
Страница 34: ...32...
Страница 76: ...74...
Страница 77: ...Operation I 1 Operation 76 2 Maintenance and repair 77 3 Dismantling 78 4 Disposal 78 75 Operation Content...
Страница 81: ......