Hotset GmbH
87
Start-up-, Service- and Operation Manual hotcontrol cDT+
Rev. 1.00.05
Subject to technical changes
13.18.3Message CAN. - No more actual values
13.18.4Message CANID - Same NodeID
CAN.
The message appears during operation, when the CAN-Bus
does no longer transfer actual values to the zone. The con-
nection controller to external sensor is interrupted / dis-
turbed.
Remedy
The component, that reg-
isters the temperature for
this zone, does not work
any longer; Problem with
CAN-Bus
Reason
Trouble Shooting
Incorrect plug connec-
tion CAN
Check connection to ribbon cable
Replace ribbon cable if necessary
Power controller card
electrical defect
Check LEDs on HTC-Card (see chapter
Replace HTC-Card (see chapter
Heating Thermocouple Card) or send Hot Runner Con-
troller in for repair
CANID
The message appears when one and the same NodeID is
detected several times on the CAN bus.
Remedy
Reason
Trouble Shooting
DIP switch setting
Check DIP switch setting