Chapter 13

Trouble Shooting

Rev. 1.00.05
Subject to technical changes

13.19Status indication on HTC-Card

On the HTC-Card are 3 LED's available.

The status of the HTC-Card can be identified by the displayed LED signals.

During fan test, the OK-LED and the ERR-LED per HTC-Card flash alternately, card by card.

Remedies in case of errors see displayed text in zone display see chapter 

Trouble Shooting.

LED

Monitor mode

Pre operational mode

Operational mode

Error see displayed 
text of zone display

OK

Faster flashing

Slower flashing

Continuous light

Continuous light

ERR

OFF

OFF

OFF

Continuous light

LED

Mode

SIO

Communication
(CAN/SIO)

Содержание hotcontrol cDT+

Страница 1: ...Rev 1 00 05 11 2017 Start up Service and Operation Manual Translation of original manual Start up Service and Operation hotcontrol cDT ...

Страница 2: ......

Страница 3: ...osal 10 Immediately after Switch ON 11 hotcontrol cDT starts 12 Dialog box for switch on of hot runner controller 13 Operation by Control User Interface general specification 14 Control User Interface CUI07 Operation gestures 15 Current view 16 Messages Symbols in Header 17 Alarm key 18 Function keys 18 Show views 19 Main keys 20 Color of key 20 Scroll 20 Pinyin 21 Main keys 22 Heating ON OFF 22 B...

Страница 4: ...nctions 73 Alarms 74 Status 75 Functions 76 Trouble Shooting 77 Sensor break TCb 78 Sensor incorrect polarity TCp 78 Sensor alarm TCs 79 Potential error Pot 79 Current tolerance error 80 Thyristor alarm Thy 80 Residual current RC 81 Current alarm Cur 81 Total breakdown of heater HBr 82 Temperature outside limit value range 82 Temperature alarm Tmp 83 Fuse failure Fus 83 Phase missing FUS 83 Heater...

Страница 5: ...ring 129 Cleaning 129 Product information Status Info Process Hot runner controller 131 Messages 132 Possible messages 133 Pairing Mode 135 Functions 138 Heating current measuring and monitoring 138 Automatic ramp 139 Heat n Dry 141 Auto Tuning Identification 142 Start up mode 143 Leading zone operation 143 Auto Standby 144 Hot Runner Controller overall functions 146 Reset password 147 USB support...

Страница 6: ...on Option 183 Alarm Output XM1 Signal Plug 184 Control fuse 184 Sensor inputs and power outputs Output plug XA 185 Power Supply 185 Replacement of single components 186 HTC 06 15 Heating Thermocouple Card Replace fuses 187 HTC 06 15 Replace Heating Thermocouple Card 189 Replace Control User Interface CUI07 190 Delivery Status Standard 191 Parameters 191 System parameters 193 Communication paramete...

Страница 7: ...u have access to the controller cards hotcontrol cDT is also optionally available with external fuses App for remote control via your Smartphone Comfortable monitoring and diagnostics Hot runner controller with output limitation and intelligent output distribution The equal control pulse distribution Smart Peak Reduction SPR reduces peak loads Ultra fast and reaction free current measurement Data ...

Страница 8: ...nce With this symbol information in another document is referred to FAQ Here FAQ Frequently Asked Questions are answered To use specifies which materials components etc are to be used Installation indicates how the installation should take place for example order arrange ment etc Cross references are marked with this character In the pdf version of the doc ument the objective of the cross referenc...

Страница 9: ...tion on this topic see document Manual hotcontrol cDT Parameters Protocol PSG II Information on this topic see protocol description PSG II and the corresponding object lists Protocol Modbus Information on this topic see protocol description Modbus and the correspond ing object lists Protocol Modbus TCP Information on this topic see protocol description Modbus TCP and the corre sponding object list...

Страница 10: ... accidents for electrical installations and equipment by govern ment safety organization in industrial facilities Do not throw packaging material careless away thermoplastic foil styrofoam parts etc may get dangerous for persons Protect device against moisture Do not use in areas with high humidity Check that the specified voltage on the type plate is identical with the mains voltage on site Ensur...

Страница 11: ... warranty claim terminates For these damages the manufacturer assumes no liability 3 2 Intended use The hot runner controller hotcontrol cDT is exclusively designed for temperature dependent control of electric heaters e g injection molds determined within the specifications More specific descriptions are given in this op erating instructions For the parameterization of customer desired functions ...

Страница 12: ...nsport and Storage 3 5 1 Transport The hot runner controller hotcontrol cDT all single components together is packed in a stable shock proofed carton This assures sufficient protection in normal case 3 5 2 Unpacking Check the packaging and then the device for identifiable damage incurred during transit If damage is identified then please get in touch with the transportation company 3 5 3 Storage I...

Страница 13: ...m used font was not loaded and or causes problems Load current firmware for CUI07 from homepage on USB stick and update firm ware see chapter Update Firmware CUI07 page 172 No firmware found Please update firmware No firmware was found Load current firmware for CUI07 from homepage on USB stick and update firm ware see chapter Update Firmware CUI07 page 172 The user language is not com patible to t...

Страница 14: ... 00 05 Subject to technical changes 4 1 hotcontrol cDT starts After successful end of boot monitor the display changes to Standard view In the Standard view the zones are represented with their important characteristics dependent on the zoom level ...

Страница 15: ...roller Is the parameter SP17 Query for MoldCheck start page 193 ON a dialog box is shown after switch on of the hot runner controller also after activation of the heating by key Selection Switch on The heaters are switched on without any further check MoldCheck call of function see chapter MoldCheck page 150 Quit Quit this dialog and change to Standard view ...

Страница 16: ...larily because settings by Infocenter page 89 may have been modified compared to the standard delivery other users not admin are logged in other programs are active other current views are shown Whether and which keys and views are enabled for the user see chapter User Ad ministration page 101 The shown examples are usually for user admin Current view page 16 Function keys page 18 Keys Show views ...

Страница 17: ... lift finger off the screen E g in header over screen edge to display Infocenter page 89 Wipe left right Touch screen with your finger pull in one direction and lift finger off the screen E g in zone view to show further zones when existing Zoom IN Zoom Two fingers are positioned on the screen and moved apart Pinch open E g zone view for Zoom IN Thus a small number of zones is dis played on the sc...

Страница 18: ...a key and the view name is displayed in the header Views see chapter Show views page 19 The shown arrows indicate that in the direction of the arrows is more information available Navigation by see chapter Con trol User Interface CUI07 Operation gestures page 15 current page of maximum pages Name of view 1 3 Standard 2 3 Standard 3 3 Standard Exemplary display ...

Страница 19: ...ler overall functions page 146 if control is stopped e g at Software Download Slave page 112 or if the system scans the HTC cards if input block is active e g if PC with installed own PC software operation software TEMPSoft2 and or via bus connection to machine control is connected if By this symbol is signalized that see chapter Process Monitoring page 160 is activated Activation of function by s...

Страница 20: ...rms page 71 There are persistent alarms By selection of the key the alarm view is displayed see chapter Alarms page 71 Group Only if Group view was selected before see chapter Show views page 19 Program The name of the activated program is displayed in the header See chapter Program page 61 Is tool coding active in hotcontrol cDT the transferred tool coding e g 00000001 from the connected tool to ...

Страница 21: ...unctions the representation of the zones can be changed Whether and which keys are enabled for the user see chapter User Administration page 101 Standard See Chapter Standard view page 34 Group See Chapter Group view page 37 Table See Chapter Table view page 38 All See Chapter View All page 39 Trend See Chapter MoldCheck view page 40 MoldCheck See Chapter MoldCheck view page 40 At last selected ke...

Страница 22: ...ter Boost page 24 Standby See Chapter Standby page 26 Login Logout See Chapter Login Logout page 27 At last selected key is displayed in yellow exception Function keys page 18 Main keys page 20 The selected key changes short ly colour to green when the key stroke was accepted as a command Example key Standard view If more information is existing than represented in the view e g parameters zones in...

Страница 23: ...er the Latin transcription From the keypad embedded over the normal keys the Chinese characters can be selected by using the arrow keys left right The entry of password for Login Logout page 27 is via standard keyboard 1 For Example input of Latin let ter a 2 Selection of symbol from key pad Further characters for a by left right arrow keys Inputs under 1 Show the following symbols in keypad 2 a 阿...

Страница 24: ...arameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated for the user see chapter User Ad ministration page 101 Press key The heating is switched on for all zones parameter P006 Zone page 191 ON Reject Confirm After switch on of the hot runner controller and or after activation of the heating by key a dialog box can be shown Details see parameter SP17 Query for ...

Страница 25: ...r a successful executed identification for one zone it is restarted after Heating ON OFF page 22 if the start conditions for the identification are fulfilled i e zone was passivated and is activated see parameter P006 Zone page 191 in between the setpoint value was set to 0 see parameter P001 Setpoint value page 191 the actual value shows no sensor break ...

Страница 26: ...ton The function can also be activated by a digital input e g from the injection molding machine In the second case the Boost mode follows the heating up After the start up time has elapsed the zones are increased by a freely selectable temperature value This workflow provides the operator at automated heating up processes because no manual interaction is necessary What good is it The Boost mode p...

Страница 27: ... Confirm In the first line actual value of the zone display the display of the text alternates with the display of the current value see chapter Alarms page 74 In the second line setpoint value of the zone display the elapsing tim er is shown see parameter P017 Boost time at start up mode page 191 Boost function active is signal ized by the green color in the key After deactivation of the Boost fu...

Страница 28: ...y is saved and the plastic located in the cavities is not thermally damaged Setting by Main keys page 20 SP09 Standby page 193 SP11 Auto Standby Time page 193 P007 Standby setpoint value page 191 For further details on parameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated for the user see chapter User Ad ministration page 101 Press key After activation of th...

Страница 29: ... key symbol for login By a login other users are activated and or deactivated after logout What good is it By User Administration page 101 and Login Logout page 27 the hot runner con troller may be individually adapted at any time in terms of the enabled function scope faulty insertions are prevented Setting by Main keys page 20 The standard passwords should be changed after start up of the system...

Страница 30: ...n in the key symbol Login User admin logged in User prof logged in A logged in user is logged off again after selection of the key symbol Login and confirmation Reject Confirm Standard passwords see chapter Change password page 105 In case the password for user prof and or user admin is unknown see chapter Reset password page 147 If no operation is performed on the device for 10 minutes the curren...

Страница 31: ...arameters views and functions are available for Standard user without login An overview you can find in chapter Delivery Status Standard page 191 When the Standard user wants to access other user prof and or all user admin parameters views functions he must log in see chapter Login Logout page 27 and or activate deactivate parameters views functions by User Administration page 101 Standard operati...

Страница 32: ...apter User Administration page 101 By Tap page 15 in zone display input di alog Select zone Example zone 1 Select parameter Example P001 By the displayed numeric key pad the specification of the new value for the selected pa rameter field can be done Example 120 Confirm entry Setpoint value change execut ed Quit dialog Further information see chapter Input dialog zones page 46 ...

Страница 33: ... manual mode Whether and which keys are enabled for the user see chapter User Administration page 101 By Tap page 15 in zone display input di alog Select zone Example zone 1 Select parameter Example P003 By the displayed numeric key pad the specification of the new value for the selected pa rameter field can be done Example 10 Confirm entry ...

Страница 34: ...32 Chapter 7 Standard Operation Rev 1 00 05 Subject to technical changes Confirm Reject Quit dialog Further information see chapter Input dialog zones page 46 ...

Страница 35: ... page 39 MoldCheck view page 40 Trend view page 42 and View Alarm page 41 On the one hand this offers the possibility to view zones in an individual favorite view on the other hand enables very convenient operation depending on the application Change can be implemented as desired between the individual representation types Show views Change setting Infor mation Center The activated and therefore o...

Страница 36: ...d with their important characteristics dependent on the zoom level The smaller the zoom level the more details are shown and vice versa Exemplary display User admin Change of view see chapter Show views page 19 See Chapter Scroll page 20 Zoom IN Zoom OUT Scroll Direct selection of zone see chapter Input dialog zones page 46 ...

Страница 37: ...l value C 0 alternately with Messages Alarms Status Functions page 73 1 C C Setpoint value C 0 C Output value A Schematic presentation Zone Smallest zoom level at 30 36 42 48 zones PM Zone number as footnote down left and zone name in the top field Actual value C 0 alternately with Messages Alarms Status Functions page 73 1 C C Setpoint value C 0 C Schematic presentation Zone Mini zoom level at 64...

Страница 38: ...larm is existing see chapter Messages Alarms Status Func tions page 73 Actual value lies within the tolerance range around the setpoint val ue Zone is passive off P006 Zone page 191 Display of zones in Hot runner controller Pair ing Mode actuator when MoldCheck is run ning Display of text MCK al ternating with actual val ue The passive zones are dimmed There were no val ues displayed See chapter p...

Страница 39: ...ayed selectable by the group name from the user For details see chapter Zone selection keys D page 50 and Edit group page 52 Pressing the GROUP key displays the defined groups in a list to choose from The first defined group is always displayed as shown Group xyz Zone 1 3 User admin Selection of zone see chapter Input dialog zones page 46 See Chapter Scroll page 20 ...

Страница 40: ...ters of the hot runner controller of all zones are dis played The settings in table are valid for the whole hot runner controller All zones all table content selected user admin Dependent on configuration see chapter Configure table view page 109 status and or parameter are displayed in the table view here Navigation in the table view in column zones by see chapter Scroll page 20 Selection of zone...

Страница 41: ...with a clear and easily visible Good Bad in formation item in the form of a color underlay of the zone Exemplary display User admin Color of the zone Actual value lies within the tolerance range around the setpoint val ue Actual value lies below the tolerance range around the setpoint value Actual value lies above the tolerance range around the setpoint val ue For the zone an alarm is existing see...

Страница 42: ...o technical changes 8 5 MoldCheck view In the MoldCheck view a complete diagnosis of electric conditions of the Hot Runner and the corre sponding peripherals is displayed For details see chapter MoldCheck page 150 Exemplary display User admin ...

Страница 43: ...usly Alarms are output when there is a devi ation from the normal status e g at limit value violation or a fault in the hardware In the view Alarm all alarms for all zones are displayed For details see chapter Alarms page 71 and chapter Messages Alarms Status Functions page 73 Exemplary display User admin Selection of zone see chapter Alarms page 71 See Chapter Scroll page 20 ...

Страница 44: ...d view In the trend view the actual value the setpoint value and the output value are displayed for maximum 6 selectable zones For details see chapter Trend settings page 43 Zone 1 2 4 6 7 8 User admin See Chapter Trend settings page 43 Select zones Change trend scaling ...

Страница 45: ...rcular buffer This provides a data capacity for all zones of 20 minutes each With filled circular buffer in data recording the oldest data will be over written What good is it The course of the values is recorded and can be analyzed easily Setting by Trend view page 42 Whether and which keys are activated for the user see chapter User Ad ministration page 101 Show trend In the basic state the tren...

Страница 46: ...og In the upper area the actual value and the setpoint value and in the lower area the output value of the selected zones are displayed Change trend scaling Select Y axis Setting of Y axis for setpoint value actual value by A temperature start and temperature end Setting of Y axis for output value by B output value start and output value end Setting of X axis by C for time A D C ...

Страница 47: ...changes Confirm each setting Adjustment range Temperature start temperature end between 0 1000 start end Output value 0 100 Time 5 10 15 20 minutes As soon as the time scale is changed and the trend is displayed again the starting point of the trend is shown in the middle of the time scale Quit dialog ...

Страница 48: ...y the displayed numeric keypad C for all selected zones F Con firmation input by ENTER key and assume it to all selected zones What good is it Operation of device Setting by View Input dialog zones page 46 Whether and which keys are activated for the user see chapter User Administration page 101 By Tap page 15 in zone display input di alog Example zone 1 A Parameter list A page 47 B The selected p...

Страница 49: ...e example P001 Setpoint value page 191 The list is circulating When the parameter list is exited and re entered the last selected parameter appears How it works The parameters can be selected and changed for the selected zones The entry is done by Numeric keypad C page 49 What good is it Zone dependent input entered in uniform dialog Setting by Parameter list A page 47 in Input dialog zones page 4...

Страница 50: ...trol cDT Description The selected parameter in Parameter list A page 47 is displayed in Parameter Field B page 48 upper left The designation characteristic analog is displayed as well as the number of the zone that is currently shown in this field How it works From Numeric keypad C page 49 the selected parameter from Parameter list A page 47 is displayed What good is it Zone dependent input entere...

Страница 51: ...alog adapts its look on the parameter to change Setting by Numeric keypad C page 49 in Input dialog zones page 46 Numerical value Increase value by key Absolute Current numerical value 100 Entered numerical value 50 After confirmation numerical value 50 Decrease value by key Relative Current numerical value 100 Entered numerical value 50 After confirmation numerical value 150 Status Change status ...

Страница 52: ...he zone selection keys Select all zones Deselect all zones Selection of group the zones are selected How it works Select zone selection keys by tap What good is it Zone dependent input entered in uniform dialog Setting by Zone selection keys D page 50 in Input dialog zones page 46 Select all zones Deselect all zones ...

Страница 53: ...t to technical changes Selection of group Is no group defined see chap ter Edit group page 52 Is exactly 1 group defined here 01 with Zone 1 3 this is taken for selection Quit dialog In the input field of Numeric keypad C page 49 the setting of the zone with the least number is displayed ...

Страница 54: ... g nozzles in a special tool area manifold zones can comfortable be combined in groups and saved with a freely specified name What good is it The possibility of grouping of zones eases the operation and saves time The groups are saved with a freely specified name and can easily be recognized by the user Setting by Zone selection keys D page 50 in Input dialog zones page 46 There is no group no gro...

Страница 55: ...bH 53 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Select zones here Zone 1 Zone 3 Select group name here 01 Change group name 01 by vi sual keyboard Confirm xyz ...

Страница 56: ...nical changes Selection of group xyz is now available for selec tion out of groups In this example is exactly 1 group defined this is taken for selection Quit dialog For each zone the assignment to a group can be changed by parameter P046 Group number page 192 ...

Страница 57: ...you copy the parameter P045 Zone name page 192 the system adds char acters to preserve the uniqueness of the name How it works The user selects a zone and the corresponding parameters which are then copied to at least one or more zones What good is it The function eases the work of setting parameters for the customer Setting by Zone selection keys D page 50 in Input dialog zones page 46 Setting ex...

Страница 58: ...e for the function appears selected Only one zone can be selected Select parameter of the zone you want to copy Example zone 2 setpoint value For the selected zone you can select any number of parameters for the copy Select all parameters Deselect all parameters Deactivate parameters Select the cross to delete it Activate parameters Select the empty field to set a cross ...

Страница 59: ...Hotset GmbH 57 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Select destination zone for copy Example zone 5 Press key Confirm Quit dialog ...

Страница 60: ...y Zone Selection Overview F page 60 can be identified which zones are overall selected for the hot runner controller How it works Select single zones by tap page 58 How it works Select zone area by double clicking page 59 What good is it Zone dependent input entered in uniform dialog Setting by DIRECT zone selection E page 58 in Input dialog zones page 46 Select single zones by tap Select single z...

Страница 61: ...quick double clicking on zone 5 Zone 1 zone 3 up to zone 5 are selected Selection of further zones see also chapter Scroll page 20 or The area between the firstly selected zone and the zones selected by double clicking is displayed as selected and color coded Quit dialog In the input field of Numeric keypad C page 49 the setting of the zone with the least number is displayed ...

Страница 62: ...act that this can not be identified in all circumstances in the scrolled DIRECT zone selection E page 58 Zone Selection Overview F page 60 is not selectable How it works By tap on the zones they are added to Zone Selection Overview F page 60 zone selected and or removed zone deselected What good is it Zone dependent input entered in uniform dialog Setting by Zone Selection Overview F page 60 in In...

Страница 63: ...d program How it works For the hotcontrol cDT hot runner controllers programs can be saved with freely selectable name internal or to the USB stick connected to the USB port The freely naming of the programs eases the recognition by the user What good is it The programs support the user at adjustment caused by often tool replacement and reduce the start up phase Setting by Function keys page 18 Pr...

Страница 64: ... already in use the user can confirm overwriting the file The program is stored with the entered name internal as seen in the example here or to USB Above the file date time of sav ing is shown in the display Stored program internal as seen in the example here or on USB is activated in the hot runner controller i e the hot runner controller takes the set ting of the parameters out of the program S...

Страница 65: ...from the header be cause the current configuration is no lon ger conform with the activated program Is option tool coding activated display 00000000 alternates with the name of the activated program in the header Stored program internal as seen in the example here or to USB is deleted Select program Press key Stored program internal can be exported on USB stick Select program Press key All stored ...

Страница 66: ...stick If available directory select able Return to previous directory The saved ptp file on USB stick can only be read from hotcontrol cDT hot runner controller Only with option Memory extension in hotcontrol cDT The key Import all programs is only with activated option visible All stored programs on the USB stick are then imported to the internal memory extension Quit dialog ...

Страница 67: ...e in hotcon trol cDT transferred tool coding e g 00000001 from the connected tool to hotcon trol cDT is visible in the header Is a program activated for the hot runner controller the pro gram name alternates with the transferred tool coding in the header display Whether and which keys are enabled for the user see chapter User Administration page 101 Allocate program and tool cod ing Press key The ...

Страница 68: ...nges Quit dialog The allocation of program and tool coding is displayed for the internal stored program Quit dialog Only internal stored programs can be allocated One tool coding can be allocated to maximal 1 program One program can be allocated several tool codings ...

Страница 69: ...s compared directly If all the parameters in a user acceptable range it can be saved as a reference for the MoldSnapshot the hot runner A MoldSnapshot only makes sense when you can compare it with a reference snapshot For hotcontrol cDT hot runner controllers characteristics are exclusively saved on a USB stick connected to USB port What good is it MoldSnapshot is a very easy to use and evaluate r...

Страница 70: ...visual key board Reject Confirm If a name is entered which is already in use the user can confirm overwriting the file MoldSnapshot is created and stored under the entered name on the USB stick Above the file date time of sav ing is shown in the display The shown file in the view can be deleted from USB stick Select MoldSnapshot Press key ...

Страница 71: ...T Rev 1 00 05 Subject to technical changes Select a directory on the USB stick If available directory select able Return to previous directory The saved CSV file on USB stick can e g imported with Microsoft EXCEL The file is stored in Unicode UTF 8 format Quit dialog ...

Страница 72: ...in the heater by comparison with reference values At current transfer only the active zones are taken into account Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Ad ministration page 101 Select function Confirm Reject Message Current transfer active After confirm Appears briefly If current transfer is executed Dialog quits by itself Any existing mes...

Страница 73: ... the view Alarm all alarms for all zones are displayed What good is it The user can get an overview quickly Setting by View Alarms page 71 Whether and which keys are activated for the user see chapter User Ad ministration page 101 Press key Alarm persistent No alarms persistent I In the alarm list the following is shown Zone 2 sensor incorrect polari ty Sensor zone 4 permuted with zone 6 Zone 7 up...

Страница 74: ...ur ther zones select further zones Key is only displayed when there are alarms to acknowledge If the reason for the alarm is no longer existing e g a sensor break is repaired the non stor ing alarms are automatically deleted from the alarm list The storing alarms must be ac knowledged Which alarms are storing because they are critical is fixed in the system see chapter Messages Alarms Status Funct...

Страница 75: ...itized There is only 1 text shown the one with the highest priority alarms in zones see chapter View Alarm page 41 Text display here OFF in the first line of the zone display alternates with current actual value Alarm Status Function Storing alarm has to be acknowledged Color change of zone on alarm Due to the fact that some display texts differ between series hotcontrol cDT and series hotcontrol ...

Страница 76: ...it in heating circuit IAL IOL n a HBr Total breakdown of heater HBr page 82 Heater not connect ed Hb n a n a Temperature outside limit value range page 82 n a Tmp Temperature alarm Tmp page 83 Temperature above max imal value tAL trG FUS Fuse failure Fus page 83 Phase missing FUS page 83 FUS Cha Channel data error Cha page 85 ERR Cha Channel data error card Cha page 85 ERR SYS System data error SY...

Страница 77: ...IdE Pm Process alarm see chapter Process Monitoring page 160 PAL n a Actual value lies above the tolerance range around the setpoint value see chapter Temperature outside limit value range page 82 n a n a Actual value lies below the tolerance range around the setpoint value see chapter Temperature outside limit value range page 82 n a Zone Display Alarm list Description pT de en OFF Zone is passiv...

Страница 78: ...ode see chapter Boost page 24 bST MCK MoldCheck page 150 Diagnostics active dIA HnD Heat n Dry page 141 HnD SUp Start up mode page 143 active AFb StA SBo Start up mode Boost running AFb StA Trp Manual temperature ramp active rAP Arp Automatic ramp page 139 active Marking slowest zone Ar Ar Automatic ramp active see chapter Automatic ramp page 139 Ar RfZ Leading zone manual mode FSt CoU PmL page 15...

Страница 79: ... explicitly described cases send the Hot Runner Controller hotcontrol cDT in for repair Below you can see how to find and eliminate errors during operation and how the messages look like in the various displays Hardware problem Trouble Shooting Touch remains dim Check control fuse LEDs on HTC card do not flash Check control fuse See Chapter Status indication on HTC Card See Chapter Replacement of ...

Страница 80: ...Remedy Reason Trouble Shooting Sensor break Check the connected sensors Check connecting cable of hot runner controller Check sensor input TCp Sensor incorrect polarity means that the thermocouple is connected with the wrong polarity to the controller How it works Due to the incorrect wiring the controller measures a faulty actual value For not yet heated tool the fault is not visible Only when th...

Страница 81: ...e to the appropriate zone the heating is turned OFF A sensor alarm can be faulty and that is when the heat out put of the zone is too small It shows an identical error im age What good is it The sensor alarm provides the user with a specific indica tion of the error in the hot runner or the wiring and provides the ability to pinpoint errors quickly and correct it Remedy Reason Trouble Shooting Sho...

Страница 82: ...rovides the ability to pinpoint errors quickly and correct it Remedy Reason Trouble Shooting Ground Check Heating Sensor at heating out put Check wiring system Tool changing without current transfer Execute current transfer Thy A thyristor alarm indicates a defective component in the hot runner controller How it works The hot runner controller checks the measurement of the heating currents whether...

Страница 83: ...provides the ability to pinpoint errors quickly and correct it Remedy Reason Trouble Shooting Tool humid Check tool on humidity Due to poor wet insulation a part of the current flows e g via the protective conductor or directly in the ground Limit value wrong Check settings for limit value and adjust it if necessary Cur On the Heating output a short circuit was detected How it works At switch on o...

Страница 84: ...npoint errors quickly and correct it Remedy Reason Trouble Shooting Wiring Check wiring system Heating Check heating measure electrical resistance Subnormal tempera ture The actual temperature value is monitored in the hot runner controller on limits An actual temperature value outside the set limits generates this alarm by changing the color of the frame of the affected zones Excess temperature H...

Страница 85: ... damage on the device and provides the user with a specific indication of the error in the hot runner Remedy Reason Trouble Shooting Partial failure of sensor Incorrect actual value display but no sensor short circuit Check sensor exchange if necessary Fus The hot runner controller controls the status of fuses in the heating circuit and output an error message in case of an defective fuse How it w...

Страница 86: ... sink limit value is exceeded What good is it Protection of hot runner controller of damages due to over heating Remedy Reason Trouble Shooting High temperature at in stallation location Check environmental conditions at installation location Overload Check Coincidence factor 100 duty ratio permanently at ambi ent temperature 25 C At ambient temperatures from 25 C to 45 C the coincidence factor ca...

Страница 87: ...C Card Is for some reason for one of these parame ters an error detected that can not be corrected the CUI Card generates a channel data error Remedy Reason Trouble Shooting Check sum error in EE PROM EEPROM OK Edit any channel parameter P Errors will be corrected after a short time by calculating the checksum Check sum error in EE PROM EEPROM de fective Replace HTC Card see chapter HTC 06 15 Repl...

Страница 88: ...d This checks whether all components in the project setup configured are existing on the CAN Bus The project setup is always checked cyclical version con trol of single components Remedy No or wrong component responds on CAN address Reason Trouble Shooting Incorrect plug connec tion CAN Check connection to ribbon cable Replace ribbon cable if necessary Incorrect plug connec tion Check hardware in ...

Страница 89: ...ters the temperature for this zone does not work any longer Problem with CAN Bus Reason Trouble Shooting Incorrect plug connec tion CAN Check connection to ribbon cable Replace ribbon cable if necessary Power controller card electrical defect Check LEDs on HTC Card see chapter Status indica tion on HTC Card Replace HTC Card see chapter HTC 06 15 Replace Heating Thermocouple Card or send Hot Runner...

Страница 90: ...nals During fan test the OK LED and the ERR LED per HTC Card flash alternately card by card Remedies in case of errors see displayed text in zone display see chapter Trouble Shooting LED Monitor mode Pre operational mode Operational mode Error see displayed text of zone display OK Faster flashing Slower flashing Continuous light Continuous light ERR OFF OFF OFF Continuous light LED Mode SIO Commun...

Страница 91: ... page 131 Messages page 132 How it works Call of function in Infocenter What good is it System setting centrally changed in one place Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Ad ministration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge A System settings page 90 B Product information Sta tus Info Process Hot r...

Страница 92: ...enter What good is it Easy change of temperature unit Setting by Key in Infocenter SP01 Temperature Unit page 193 For further details on parameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Temperature unit in F Press key The temperat...

Страница 93: ...Hotset GmbH 91 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Quit dialog Temperature unit F in stan dard view Press key again to reset tem perature unit ...

Страница 94: ...ey in Infocenter What good is it Adjustment for right or left handers Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Key arrangement left Press key The key arrangement changes between right and left On touch the key appears se lected Key arrangement left Q...

Страница 95: ...Hotset GmbH 93 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Key arrangement left in stan dard view Press key again to reset key arrangement ...

Страница 96: ...What good is it Change of the physical unit for the connected heating Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Physical unit Watt Press key The displayed physical unit in the zone can be changed be tween heating current A and heating power W On touch...

Страница 97: ...Hotset GmbH 95 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Physical unit heating power W in standard view Press key again to reset phys ical unit ...

Страница 98: ...Monitor the floating current in the heater by comparison with reference values Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Activate current transfer Press key On touch the key appears se lected Confirm Reject Message Current transfer active After confir...

Страница 99: ...ical changes Current transfer executed Any existing message Cur rent setpoint value is not set page 133 is reset after a successful current transfer if the current transfer was exe cuted for all zones Quit dialog See also chapter Messages page 132 See also chapter Activate current transfer page 70 ...

Страница 100: ...center Specify system parameters which are unique and zone independent What good is it Simple adaptation of hotcontrol cDT hot runner controllers e g at integration in company networks Setting by Key in Infocenter For further details on parameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocen...

Страница 101: ...ol cDT Quit dialog Description Each hotcontrol cDT hot runner controller is delivered with a standard setting of parameters Furthermore the user can adapt the system to individual requirements by communication parameters How it works Call by key in Infocenter Specify communication parameters which are unique and zone independent What good is it Simple adaptation of hotcontrol cDT hot runner contro...

Страница 102: ...cation param eter out of the communication parameter list is displayed in the parameter field up per left C By the displayed numeric keypad the specification of the new value for the se lected parameter field can be done Further details on data entry see chapter Numeric keypad C page 49 For further details on communication parameters see Manual Parameters hotcontrol cDT Quit dialog B C A ...

Страница 103: ...ation The user administration allows the customization of the enabled functionality to the needs of each customer and can be made by himself Standard operation Standard user without password Professional operation user prof with freely selectable password System administrator operation user admin with freely selectable password What good is it In times in which 100 quality parts must be provided f...

Страница 104: ...n touch the key appears se lected The subsequent displayed settings are exemplary and dependent on the user and on chapter Delivery Status Standard page 191 Parameters for Standard user Exemplary display adjustable System parameters for Standard user Exemplary display adjustable ...

Страница 105: ...0 05 Subject to technical changes Communication for Standard user Exemplary display adjustable Views page 33 for Standard user Exemplary display adjustable Functions for Standard user Exemplary display adjustable Infocenter page 89 for Standard user Exemplary display adjustable ...

Страница 106: ...chapters in this Start up Service and Operation Manual The procedure for settings for standard user and user prof is identical Deactivation Select the cross to delete it Activation Select the empty field to set a cross Instead of selection Deselection of single settings Select all fields Deselect all fields Quit dialog ...

Страница 107: ...f User admin Standard password admin The function Change password page 105 is only available for user admin who has to be logged in see chapter Login Logout page 27 Display Infocenter by Wipe down page 15 in the header over screen edge User Administration Press key On touch the key appears se lected The subsequent displayed settings are exemplary and dependent on the user and on chapter Delivery S...

Страница 108: ...yboard Each entered character is prompted in plain text Example enter prof123 Reject Confirm If an already used password is entered an error message is displayed The entered password is ac cepted and prompted in plain text Quit dialog The procedure for settings for user prof and user admin is identical ...

Страница 109: ... a file as a so called USB key on a connected USB stick Dialog to change password for user admin Procedure see Change password page 105 for user prof The function is only available for user admin who has to be logged in see chapter Login Logout page 27 Display Infocenter by Wipe down page 15 in the header over screen edge User Administration Press key On touch the key appears se lected View after ...

Страница 110: ...f a list Example user prof A file KEY pT is exported on a connected USB stick Only one file is permissible per USB stick The lastly exported key can be used for login see chapter Login Logout page 27 Is the file already existing on the USB stick the file can be overwritten after confirmation Confirm Quit dialog ...

Страница 111: ...le are valid for the whole hot runner controller How it works Call by key in Infocenter The table is configured by the user by marking of status and or parameters What good is it Individual combinable table to view status and or parameters of all zones Setting by Key in Infocenter For further details on parameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated f...

Страница 112: ...mmunication parameters see Manual Parameters hotcontrol cDT Select the cross to delete it Select the empty field to set a cross Sets in all fields the cross Select all fields Deletes in all fields the cross Deselect all fields All status and all parameters are selected The table view looks as adjoin ing Navigation in the table view by see chapter Scroll page 20 B A A B C D A B C D ...

Страница 113: ...peration Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes 2 status A B and all parame ters are selected The table view looks as adjoin ing Navigation in the table view by see chapter Scroll page 20 Quit dialog A B C D A B C D ...

Страница 114: ...k in hotcontrol cDT The whole USB stick is read Call by key in Infocenter What good is it hotcontrol cDT may be adapted quickly at any time concerning bug fixes as well as new functionality Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Call up homepage www hotset com and search there for the product In the download area you ...

Страница 115: ...ges Select type The selected type is marked Files for the firmware update appropriate to the component are displayed in a list and can be selected by the user Select file The selected file is marked Select component Instead of selection deselection of single components Select all fields Deselect all fields ...

Страница 116: ...al changes The selected component is marked Press key Confirm download HEX File is being loaded and tested Please wait Adjoining message appears Update is executed Wait for end of function Waiting for slave to boot up Note appears Please follow instructions ...

Страница 117: ...Hotset GmbH 115 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Display of result Quit dialog Quit dialog or make a new selection ...

Страница 118: ...restores the original condition of the delivery state of the device 4 Fan test page 120 Fan test checks the built in fans in the hot runner controller and proofs their function What good is it 1 When adding or removing HTC card a new configuration can be created 2 In case of a problem it can easily be detected whether the current firmware is on the HTC Card If not the firmware can be updated see c...

Страница 119: ...s se lected Scan determines the currently existing firmware on the HTC cards and the connected HTC cards to the hot runner controller and the result is stored in the configuration For NodeID 1 2 the compo nents were determined For NodeID 3 no component can be determined HTC card e g was removed Configuration was changed Quit dialog or continue with ...

Страница 120: ...on Press key On touch the key appears se lected Read software version determines the currently available firmware on the configured HTC Card For NodeID 1 2 version could be read For NodeID 3 version could not be read HTC Card e g removed Configuration remains Quit dialog or continue with ...

Страница 121: ...ed The factory setting defines settings for Parameters System parameters ommunication parameters In Outputs directly at the time of delivery This factory setting is available for the under admin to load These settings are loaded from hotcontrol cDT into the Hot Runner Controller Reject Confirm If the factory setting is loaded a RESTART is executed by hotcontrol cDT Restart ...

Страница 122: ...rocess see chapter Immediately after Switch ON page 11 Fan test Press key On touch the key appears se lected Fan test checks the built in fans in the hot runner controller and proofs their function The checked fans are shown Wait for end of function Quit dialog or continue with ...

Страница 123: ...nd then be selected Language files are available on the homepage in the download area see chapter Up date language file page 175 What good is it hotcontrol cDT is quickly customizable to the language of the user Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen ed...

Страница 124: ...122 Chapter 14 Infocenter Rev 1 00 05 Subject to technical changes The user selects the preferable language out of a list The selected language is im mediately activated for the system Quit dialog ...

Страница 125: ...ends in hotcontrol cDT Setting by Key in Infocenter Whether and which keys are activated for the user see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Press key On touch the key appears se lected A Selection of the field to be changed day month year hours minutes in the right area B Selection is shown upper left C By the displayed nume...

Страница 126: ...124 Chapter 14 Infocenter Rev 1 00 05 Subject to technical changes Quit dialog The changed date time is shown in the header All time stamped data get this setting ...

Страница 127: ...f functional states in which the hot runner controller is Multiple states functions may be issued by or function Adjustable High Low active How it works The hot runner controller issues the signal for enabling of the machine by this Hereby the proper status of the hot runner is signalized to the injection molding machine The hot runner controller receives for example signals for Boost and Standby ...

Страница 128: ...ser see chapter User Administration page 101 Display Infocenter by Wipe down page 15 in the header over screen edge Press key On touch the key appears se lected Setting Input1 By selection of the filed param eter here for Input 1 1 charac teristic can be activated and or deactivated Characteristic active Characteristic deactive ...

Страница 129: ... Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Quit dialog Only 1 characteristic can be set per digital input The selectable characteristics for input 1 2 are identical ...

Страница 130: ...Display Infocenter by Wipe down page 15 in the header over screen edge Press key On touch the key appears se lected Setting output 1 By selection of the field of the parameter here at output 1 several characteristics can be added from the list of value by activating and be deleted by deactivating the cross Select the cross to delete it Select the empty field to set a cross ...

Страница 131: ...These should be removed from time to time How it works By key the Control User Interface CUI07 is desensitized for maximum 15 s and ac cepts no keystrokes During this time the display can be cleaned with a lint free micro fiber cloth Cleaning should be done with light circular movements possible without pressure on the display For tough dirt use a cloth lightly moistened with water What good is it...

Страница 132: ...130 Chapter 14 Infocenter Rev 1 00 05 Subject to technical changes Timer is running After the timer elapsed the In focenter is displayed again Quit dialog ...

Страница 133: ...Mains voltage hotcontrol cDT Version Firmware of Control User Interfaces CUI07 In case of any problem please contact the manufacturer supplier with the above not ed details Status Info Process Hot runner controller Residual current See Chapter Residual current RC page 81 Cycle signal Display of number of injection cycles indicat ed by external signal I O See Chapter Inputs Outputs page 125 Tool co...

Страница 134: ... Infocenter page 89 What good is it The message in Infocenter page 89 indicates problems or conditions to the user and proposes an action to correct the problem A part of the messages can directly be ac knowledged here and the open issue be solved Setting by n a For further details on parameters P SP CP see Manual Parameters hot control cDT Whether and which keys are activated for the user see cha...

Страница 135: ... page 96 Message Process monitoring not activated Proposed measure Activate process monitoring Details Is the process monitoring not activated although the learning phase is termi nated the user receives this message See Chapter Process Monitoring page 160 Message Wrong zone type set Proposed measure Take over zone type Details The zone type was identified as wrong Prerequisites Sensor short circu...

Страница 136: ...rror at Pairing Mode hot runner controller in operation Details In order to prevent a switched on or in production hot runner controller from being connected the latter rejects the connection request Remedy On the requested hot runner controller ensure that the heaters are switched off before a connection can be established via Pairing Mode Further details on function see chapter Pairing Mode page...

Страница 137: ... Switch Pairing Mode on Messages for Pairing Mode in hot runner controller Pairing Mode active see chapter Messages page 132 What good is it With the Pairing Mode the number of zones of a hot runner controller hotcontrol cDT can be expanded very quickly and easily The hot runner controller which has been created by the coupling can have a maximum of 192 zones 126 zones can be added at maximum via ...

Страница 138: ...address of the hot runner controller to be con nected 2 Switch Pairing Mode on The hot runner controller to be connected takes over the settings for the parameters from the hot runner controller Pairing Mode active Example If the heating is switched on the heating is switched on immediately after coupling for the coupled zones Check parameters possibly after Pairing BEFORE switching on hot runner ...

Страница 139: ...ner con troller Display Hot runner controller Pairing Mode actuator The first zone receives the next consecutive zone number from the hot runner control ler Pairing Mode active ex ample here 19 In the header the embedded symbol and the text indicates that the hot runner controller is in Pairing Mode Depending on the zone num ber the actual value the out put value and the current are displayed The ...

Страница 140: ... supports a number of controller functions For example bad adjustments of control parameters can be avoided because the automatic parameter identification auto tuning is only started if a corresponding heating current is recognized in the control zone i e when it is certain that the zone is ready for heating Else the starting of the identification function is delayed until a heating current is rec...

Страница 141: ...expansions of steel which cause unwanted mechanical tensions How it works The automatic ramp function was developed to eliminate the causes of mechanical tensions All zones are uniformly heated up All zones orientate themselves automat ically on the slowest zone Its actual value is a reference for the setpoint value for the other zones What good is it With this measure all zones remains at heating...

Страница 142: ...hanges Example Temperature trend of two zones with different rate of rise with activated automatic ramp After Heating identifica tion of zone 1 2 both zones are heated up uni formly together depend ing on the slowest zone here zone 1 to the final setpoint value ...

Страница 143: ... their preset set point values While the Heat n Dry function is running no current measuring is executed By the parameter see SP05 Maximum residual current page 193 the maximum admissible value for the leak age current is set The function can be activated deactivated by the parameter P027 Heat n Dry page 191 The function Heat n Dry has priority to function see function Start up mode page 143 Descr...

Страница 144: ...alue jump of 40 K What good is it The hot runner controller adapts itself to the factors of the connected control system Setting by P030 Identification page 191 P031 Loop control page 191 P032 Cutback page 191 For further details on parameters P SP CP see Manual Parameters hot control cDT Text in zone display see chapter Messages Alarms Status Functions page 73 1 After a setpoint value jump from 0...

Страница 145: ... page 191 For further details on parameters P SP CP see Manual Parameters hot control cDT Text in zone display see chapter Messages Alarms Status Functions page 73 Description With a defective sensor the zone must not inevitably be switched off or immediately be repaired How it works There are two alternative functions for solution of the problem The first is the manual mode the second the leading...

Страница 146: ...d only for temperature monitoring not for temperature control their set point values should preferably be set to 0 C equivalent to zone passive Description The hot runner controller offers an Auto Standby function Herewith the hot runner controller monitors a cyclically recurring signal from the injection molding machine and sets the controller when the signal fails to appear within an adjustable ...

Страница 147: ...njection molding machine Control Auto Standby Signal edge is detected Time to check the Auto Standby is restarted Time to check the Auto Standby has expired No signal edge is detected Zones are set in standby Setpoint value Standby Setpoint value Example for digital input triggered by positive edge SP11 Auto Standby Time ...

Страница 148: ...ot runner controller H1 6 Zone H2 12 Zone are connected by CAN bus with each other Set unique NodeID Setting SP06 1 on 1 hot runner controller H1 Zone 1 6 first hot runner controller H1 SP06 7 on 2 hot runner controller H2 Zone 7 18 second hot runner controller H2 Automatic ramp page 139 The function runs only for zones where the function is activated Start up mode page 143 The function runs only ...

Страница 149: ...n be changed by the user administration What good is it In urgent cases it may be necessary to operate functions menus and or parameters which are not available for the user Is the person that knows the password not present or the password was forgotten the operation is in such an emergency possible after appropriate activation Setting by Login Logout page 27 The standard passwords should thereaft...

Страница 150: ...d quality assurance How it works Functions that save and or load data on and or from the USB stick are enabled for the user as soon as an USB stick is recognized on the USB port What good is it For data analysis or for queries of the customer thus can be used more information This makes the service easier faster more professional With this feedback the customer may be sent back corrected data whic...

Страница 151: ...e 141 Start up mode page 143 How it works By the zone parameter P047 0 the zones are grouped into a relay group The ascending relay group number defines the order of heating up Setting P047 0 Zones heat up directly independent from function relay heating Setting P047 1 Zones heat up directly after fulfilled start up conditions and give re lease to relay group 2 after reaching the setpoint value ba...

Страница 152: ...rical system of the hot runner as well as for the molders who will control the status of the hot runner before installation of the tool on the machine What good is it Early enough analysis can reduce downtimes before production Electrical control of the hot runner controller is possible without specialized knowledge The function pro vides concrete information for improvement and trouble shooting S...

Страница 153: ...ify MoldCheck waiting time for selected zones By the displayed numeric keypad the specification of the new value for the selected zone here Zone 1 can be done Instead of selection single zones see chapter Zone selection keys D page 50 Selection of group see chap ter Edit group page 52 Select all fields Deselect all fields For further details on parameters P SP CP see Manual Parameters hotcontrol c...

Страница 154: ...only valid during execution of function MoldCheck The parameter P028 MoldCheck max wait time page 191 is not changed The next function call works with the stored value in the parameter again Should the parameter permanently be changed the parameter P028 MoldCheck max wait time page 191 must be adapted see chapter Parameter list A page 47 Checking temperature rise for selected zones Each selected z...

Страница 155: ... get a closer look on the re sult press key MoldCheck result zone 1 A Current values for analysis of zone B Error if existing MoldCheck result zone 2 etc Help key without function Zone OK By the shown help key the user could display further notes see chapter MoldCheck Trouble Shooting page 157 The zone has faults Quit dialog B A ...

Страница 156: ...ored on the USB stick Press key Is no USB stick connected a message is shown The result of MoldCheck of the hot runner controller is only available as long as the function is not exit and or quit Press key Confirm on save Cancel By selection of the name it can be changed by the visual key board ...

Страница 157: ...ject Confirm Save MoldCheck result is stored with the entered name on USB stick Cancel If a name is entered which is already in use the user can confirm overwriting the file MoldCheck result is stored with the entered name on USB stick The shown file in the view can be deleted from USB stick Select file Press key ...

Страница 158: ...vious directory The saved CSV file on USB stick can e g imported with Microsoft EXCEL The file is stored in Unicode UTF 8 format Quit dialog Is the function MoldCheck exited without storing the result before the user has to confirm that the data is no longer available in the hot runner controller At the end of MoldCheck the heaters are deactivated ...

Страница 159: ...er 3 Read power value off table in Operat ing Instructions Hot Runner Controllers and compare it with the connected value of the heating output Short circuit Short circuit on power output Check feed line for short circuit 1 Remove connecting cable of Hot Run ner Controller 2 Measure resistance at terminal with multimeter 3 For resistance equals 0 Ohm fault in cable or feed line of heating in mold ...

Страница 160: ...ed LED on all power controller cards 1 YES 1 1 Check main fuse and exchange de fective fuses 1 2 Check power cord 2 No only on the appropriate power controller card of the zone 2 1 Switch off power supply 2 2 Lock card 2 3 Red LED still flashing exchange power controller card Measured current with switched off heating Power output defective Exchange power controller card of the appropriate zone No...

Страница 161: ...ck the connected sensors 1 Remove connecting cable of Hot Run ner Controller 2 Measure resistance of sensor with multimeter 3 Infinite resistance means no sensor existing or sensor defective Sensor defective or no sensor connected Sensor wrong connected Check the pin assignment of connecting cable and of mold Sensor permuted The sensor or the heating of the zone was connected to the connection of ...

Страница 162: ...he process parameters It is possible that there will be false alarms and leaks can not be detected This usually depends on structural conditions in the hot runner as well as on a faulty operation How it works The status of the zones in the hot runner is supervised by process monitoring with the help of characteristics determined during the learning phase operating point tolerance band Is the funct...

Страница 163: ...isplay Infocenter by Wipe down page 15 in the header Press key First check the setting of the system parameters SP07 Process monitoring mode page 193 and change if applicable On touch the key appears se lected Select parameter As default the function process monitoring is switched off passive The following modes are available passive Fully automatic Manual Intelligent Process Monitoring deactivat ...

Страница 164: ...ing Rev 1 00 05 Subject to technical changes See Chapter Process Moni toring Mode Fully automatic page 166 See Chapter Process Moni toring Mode Manual page 168 See Chapter Process Moni toring Mode Intelligent page 163 Quit dialog ...

Страница 165: ...r P025 Proc monitor tolerance page 191 In the illustrated example the sequence is shown if no learning phase had previously been running The header is displayed when the process monitoring is switched on See SP07 Process monitoring mode page 193 0 Process Monitoring Mode In telligent is specified In the standard view after switch on of the heaters of the hot runner controller In the first line of ...

Страница 166: ... lected OR Switching on the heaters of the hot runner controller and pro cess monitoring mode Intelli gent the adjacent dialog box is displayed Start learning phase Start learning phase see P rocess monitoring learning phase Mode 1 page 165 Remind After 5 minutes the dialog is again displayed to remind Cancel Cancel dialog the dialog will be shown again when the heaters are switched off and on aga...

Страница 167: ...shown The monitoring starts automatically following the learning phase The process monitoring is active and supervises the status of the zones in the hot runner In the first line of the zone display the display Pm process alarm see chapter Messages Alarms Status Functions page 73 alternates with the display of the current value here 100 C when the tolerance limit is exceeded at activat ed monitori...

Страница 168: ...xample the sequence is shown if no learning phase had previously been running The header is displayed when the process monitoring is switched on See SP07 Process monitoring mode page 193 0 Process Monitoring Mode Ful ly automatic is specified Learning phase starts automatically Process monitoring learning phase In the standard view after switch on of the heaters of the hot runner controller In the...

Страница 169: ...he zones in the hot runner In the first line of the zone display the display Pm process alarm see chapter Messages Alarms Status Functions page 73 alternates with the display of the current value here 100 C when the tolerance limit is exceeded at activat ed monitoring The alarm can be output on an output and be used for further pro cessing e g as Stop Machine The alarm message see chapter Messag e...

Страница 170: ...rance not displayed Parameter P025 Proc monitor tolerance page 191 remains un changed In the illustrated example the sequence is shown if no learning phase had previously been running The header is displayed when the process monitoring is switched on See SP07 Process monitoring mode page 193 0 Process Monitoring Mode Manual is specified In the standard view after switch on of the heaters of the ho...

Страница 171: ... the key appears se lected OR Switching on the heaters of the hot runner controller and pro cess monitoring mode Intelli gent the adjacent dialog box is displayed Start learning phase Start learning phase see P rocess monitoring learning phase Mode 1 page 165 Remind After 5 minutes the dialog is again displayed to remind Cancel Cancel dialog the dialog will be shown again when the heaters are swit...

Страница 172: ...ing phase Mode 2 In the standard view In the first line of the zone display the display PmL process monitoring learn ing phase see chapter Messages Alarms Status Functions page 73 al ternates with the display of the current value here 100 C Wait for end of function In the standard view In the first line of the zone display the display of the current value here 100 C is shown The monitoring starts ...

Страница 173: ...rent value here 100 C when the tolerance limit is exceeded at activat ed monitoring The alarm can be output on an output and be used for further pro cessing e g as Stop Machine The alarm message see chapter Messag es Alarms Status Functions page 73 can be acknowledged as soon as the control characteristic returns to nor mal error fixed otherwise the alarm is activated immediately again Mode Mode M...

Страница 174: ... directory Control User Interface firmware HEX file cDT CUI07 version hex Language file pT Lang language pT the update process starts 16 1 Update Firmware CUI07 Do NOT remove the USB stick during the whole update process To start firmware update Press key Select HEX file when several listed and start update by Press key Hex file for firmware update cDT CUI07wwjji hex ww calendar week jj year i Ind...

Страница 175: ...p Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes Confirm selection Cancel Please wait until all steps are executed Quit dialog by Press key Quit menu and start hotcontrol cDT by Press key ...

Страница 176: ...174 Chapter 16 Update Process Rev 1 00 05 Subject to technical changes Or load language file see chapter Update language file page 175 Further process see chapter hotcontrol cDT starts page 12 ...

Страница 177: ... Update language file Do NOT remove the USB stick during the whole update process To start language file update Press key Select language file here French when several listed and start update by Press key Cancel Language file for update pT Lang language pT Available languages please see homepage www hotset com Wait ...

Страница 178: ...rocess Rev 1 00 05 Subject to technical changes Quit dialog by Press key Quit menu and start hotcontrol cDT by Press key Or see chapter Update Firmware CUI07 page 172 Further process see chapter hotcontrol cDT starts page 12 ...

Страница 179: ...rol User Interface 07 succeeding called CUI07 HTC 06 15 Heating Thermocouple Card succeeding called HTC card The concept of hotcontrol cDT provides 2 desktop housings The desktop housings are equal in height and depth You can find the latest technical data on all products at any time on the homepage www hotset com Device specific data on type article number serial number voltage and power are on t...

Страница 180: ...178 Chapter 17 Technical Data Rev 1 00 05 Subject to technical changes 17 1 hotcontrol cDT ...

Страница 181: ...ntical You can swap freely during maintenance 18 1 Rear side Hot Runner Controller Connections Behind the rear side of hot runner controller hotcontrol cDT are connections for Power Supply Main switch Sensor inputs and power outputs Output plug XA Control fuse Alarm Output XM1 Signal Plug Digital inputs XM3 DIO Interface XS1 RS485 Interface XS2 CAN Interface XS3 RJ45 Interface XS5 20 mA Option Int...

Страница 182: ...cation Label Plug XA Assignment see specification wiring diagram Main switch main switch Alarm output XM1 Alarm Control fuse control fuse Interface XS3 RJ45 Dig In Outputs XM3 DIO Interface XS2 CAN Interface XS1 RS485 Exemplary figure rear wall hotcontrol cDT 24 Desktop housing for up to 24 zones without options Power Supply feed line ...

Страница 183: ...Interface XS1 RS485 18 1 1 2 Interface XS2 CAN XS1 Serial interface COM RS485 D SUB socket Pin Function signal 1 TX RS485 2 TX RS485 3 n a 4 n a 5 RX RS485 6 RX RS485 7 n a 8 n a 9 0V RS485 XS2 Interface CANopen CAN D SUB plug Pin Function signal 1 n a 2 CAN L CAN 3 CAN L CAN at Master Slave 4 n a 5 n a 6 n a 7 CAN H CAN 8 CAN H CAN at Master Slave 9 n a ...

Страница 184: ...ter Alarm Output XM1 Signal Plug 18 1 2Interface XS3 RJ45 XM3 2 Digital inputs DI D SUB socket Pin Function signal 1 I1 Digital input 1 2 n a 3 0V Reference potential I 4 n a 5 n a 6 I2 Digital input 2 7 n a 8 n a 9 n a Digital input XM3 Pin 1 6 I External auxiliary voltage 24 VDC XM3 PIN 3 0V External auxiliary voltage 0 VDC XS3 Interface Ethernet RJ45 RJ45 Socket ...

Страница 185: ...Vus certification is not applied Only one interface can be operated either Interface XS1 RS485 or Interface XS5 20 mA Option if both are established The 20 mA interface is established on the rear wall of hotcontrol cDT below XS1 XS2 XM3 when existing XS7 Interface external operation Option Ethernet CAN 24VDC Hybrid flush type socket wall bushing 8 poles The interface XS7 for external operation is ...

Страница 186: ...he electronics Illustration HTS plug 4 pole XM1 Signal plug XM1 Signal plug Option HTS plug 4 pole 3 pole PE HTS plug 5 pole 4 pole PE Pin Function signal Pin Function signal 1 1 2 2 3 n a 3 4 4 5 5 pole HTS plug for XM1 is only re leased by manufacturer when the device is deployed in markets where cTUVus certification is not applied Rated output current 1 A Rated voltage 250 VAC ohmic load In cas...

Страница 187: ...ion and according to the appropriate type of use in each country Consider the maximum ambient temperature at selection of cables The connecting cables for power outputs heaters may only be connected in de energized status The connecting cables must be designed for an operating voltage of 250VAC and overvolt age category II At the plug contacts of the output plugs XA can be a dangerous voltage in t...

Страница 188: ... single components for maintenance note Security References page 8 necessarily Work like e g maintenance and repair for hotcontrol cDT may be carried out by authorized and skilled qualified personnel only Only qualified personnel skilled and on the risks trained may use the hotcontrol cDT The relevant accidental regulations as well as other general ap proved safety relevant occupational medical no...

Страница 189: ...ntrol cDT Working on hotcontrol cDT may be carried out by authorized and skilled qualified personnel only Fuse for heating Use ONLY fuses of type SIBA FF 16A Art No 7012540 16 The action concerning the handling of ESD devices must be observed Electrostatic sensitive devices Deenergize hot runner controller Unlock and open front door by double bit lock Desktop housing Cards count at hotcontrol cDT ...

Страница 190: ... check that hotcontrol cDT is running correct after exchange of fuses on the components Replace fuse on card 1 Loosen card locking and ensure that the loosened screws do not fall into the device Lift the card out of the slot carefully 2 Replace fuses F1 1 F1 2 F6 1 F6 2 Look for right fit Insert card carefully into the slot into the guide brackets top bottom and regard the latching of the connecto...

Страница 191: ... in de energized status of hotcontrol cDT Working on hotcontrol cDT may be carried out by authorized and skilled qualified personnel only The action concerning the handling of ESD devices must be observed Electrostatic sensitive devices Deenergize hot runner controller Unlock and open front door by double bit lock Desktop housing Cards count at hotcontrol cDT desktop housing from right to left hot...

Страница 192: ... 3 Replace Control User Interface CUI07 If it is necessary to replace a Control User Interface CUI07 you should first contact the manufacturer supplier for advice Replace card 1 Loosen card locking and ensure that the loosened screws do not fall into the device Lift the card out of the slot carefully Set DIP switch of the spare card identical to the removed card Insert spare card carefully into th...

Страница 193: ... 500 0 O X Parameters P011 Upper relative limit value 5 0 X X Parameters P012 Lower relative limit value 5 0 X X Parameters P013 Upper absolute limit value 500 0 O X Parameters P014 Lower absolute limit value 0 0 O X Parameters P015 Start up mode ON n a X X Parameters P016 Start up time 15 0 min X X Parameters P017 Boost time at start up mode 0 0 min X X Parameters P018 Boost time 0 0 min X X Para...

Страница 194: ...4 Proportional band 9 9 O X Parameters P035 Derivative time 2 s O X Parameters P036 Integral time 10 s O X Parameters P037 Sampling time 0 5 s O X Parameters P038 Zone type 0 n a O X Parameters P039 Limit value hysteresis 1 0 O X Parameters P040 Sensor type 1 n a O O Parameters P041 Monitoring of sensor TCs OFF n a O X Parameters P042 External sensor NodeID 0 n a O O Parameters P043 External senso...

Страница 195: ...rent 60 0 mA O X System parameters SP06 Offset zone numbering 1 n a O X System parameters SP07 Process monitoring mode 0 n a X X System parameters SP08 Boost OFF relative O X System parameters SP09 Standby OFF relative O X System parameters SP10 Heat sink limit value 80 O X System parameters SP11 Auto Standby Time 0 0 min O X System parameters SP12 Operating setpoint limit value relative ON n a O ...

Страница 196: ...tion CP10 ETH IP address 2 168 n a X X Communication CP11 ETH IP address 3 0 n a X X Communication CP12 ETH IP address 4 220 n a X X Communication CP13 ETH Subnet mask 1 255 n a X X Communication CP14 ETH Subnet mask 2 255 n a X X Communication CP15 ETH Subnet mask 3 255 n a X X Communication CP16 ETH Subnet mask 4 0 n a X X Communication CP20 ETH Gateway 1 0 n a X X Communication CP21 ETH Gateway...

Страница 197: ... Table view page 38 X X Views View All page 39 X X Views Trend view page 42 X X Views MoldCheck view page 40 X X Type Charac teristic Description Key USB S P Functions Program page 61 load X X Functions Program page 61 save X X Functions Program page 61 delete O X Functions Program page 61 export X X Functions Program page 61 import X X Functions MoldSnapshot page 67 create X X Functions MoldSnaps...

Страница 198: ...o center System parameters page 98 Info Center X X Info center Communication page 99 Info Center O O Info center Configure table view page 109 Info Center X X Info center Software Download Slave page 112 Info Center O X Info center Hardware Setup page 116 Info Center O O Info center Language page 121 Info Center O X Info center Date Time page 123 Info Center O O Info center Inputs Outputs page 125...

Страница 199: ...97 Start up Service and Operation Manual hotcontrol cDT Rev 1 00 05 Subject to technical changes 21 Appendix 21 1 Consumable and Spare Parts Heating Thermocouple Card 89180301 00 HTC 06 15 Heating Thermocouple Card ...

Страница 200: ...mization for firmware from version CUI072417A In detail the following amend ments corrections were made Process Monitoring specified Pairing Mode MoldCheck help key Pinyin keyboard User prof admin specified Automatic logout added Symbols in header added Colour coding for zone added 1 00 02 2 10 2017 In detail the following amendments corrections were made Figures views updated 1 00 01 11 30 2016 I...

Отзывы: