15.13.4Process monitoring at a glance
For all modes:
1
The learning phase is executed for zones where NO process alarm is persistent.
2
The learning phase is executed for zones where parameter
[P025]Proc.monitor. tolerance (page 191) <> 0.
(Not in mode: Intelligent)
3
By setting of parameter
[P025]Proc.monitor. tolerance (page 191) = 0 a zone can be excluded from process
monitoring.
4
The learning phase can be activated or re-triggered at any time via the embedded button in the Infocenter.
5
The parameters of process monitoring could be changed by the user manually. The learning phase should not
run at that time.
In the first line of the zone display, the
display
Pm
- process alarm (see chapter
Messages - Alarms, Status, Functions
(page 73)) alternates with the display of
the current value (here: 100 °C), when
the tolerance limit is exceeded at activat-
ed monitoring. The alarm can be output
on an output and be used for further pro-
cessing e.g. as „Stop Machine“. The
alarm message (see chapter
es - Alarms, Status, Functions (page
73)) can be acknowledged, as soon as
the control characteristic returns to nor-
mal (error fixed), otherwise the alarm is
activated immediately again.
Mode
Mode
Mode
[SP07]Process monitoring mode (page 193)
Fully automatic
Manual
Intelligent
Learning phase starts
Automatic
1) 2)
Manual
1) 2)
Manual
1)
Activation learning phase key in Infocenter
4)
yes
yes
yes
Dialog box to start learning phase
no
yes
yes
Dialog box to remind
no
yes
yes
Dialog box to cancel
no
yes
yes
Display in standard view
[P025]Proc.monitor. tolerance (page 191)
2) 3) 5)
Auto save
no
Auto save
[P026]Proc.monitor. operating point (page 191)
5)
Auto save
no
Auto save
Temporary determination / display of operating
point
no
Table view
no
Monitoring starts after learning phase
Automatic
Automatic
Automatic
Start dialog box of process monitoring
no
no
yes
Display process alarm