20.2 System parameters
In Pairing Mode PM all settings for the system parameters [SP**], which are defined in the hot runner control-
ler#Pairing-Mode-active, are valid for all zones.
Exception: settings of system parameters [SP**], marked with # in row PM, are device specific.
Type
Charac
teristic
Description
Default-
Setting
Unit
S
P
PM
System parameters
[SP01]Temperature Unit
ON
°C
O
X
System parameters
[SP02]Automatic ramp tolerance band
20.0
*)
O
X
System parameters
[SP03]Automatic ramp setpoint value change
30.0
*)
O
X
System parameters [SP04]Identification of potential on sensor input
ON
n.a.
O
X
#
System parameters
[SP05]Maximum residual current
60.0
mA
O
X
#
System parameters
[SP06]Offset zone numbering
1
n.a.
O
X
#
System parameters
[SP07]Process monitoring mode
0
n.a.
X
X
System parameters
[SP08]Boost
OFF
relative
O
X
System parameters
[SP09]Standby
OFF
relative
O
X
System parameters
[SP10]Heat sink limit value
80
*)
O
X
#
System parameters
[SP11]Auto Standby Time
0.0
min
O
X
System parameters [SP12]Operating setpoint limit value relative
ON
n.a.
O
X
System parameters [SP13]Switch-on delay
0
s
O
X
System parameters
[SP14]Passive zones present dimmed
ON
n.a.
X
X
#
System parameters [SP15]MoldCheck rapid test
OFF
n.a.
O
X
System parameters [SP16]Storing alarm status
OFF
n.a.
O
X
System parameters
[SP17]Query for MoldCheck start
OFF
n.a.
O
X
System parameters [SP18]Application
OFF
n.a.
O
X
System parameters [SP19]MoldCheck End temperature
70.0
*)
O
X
System parameters [SP20]Mains voltage
230
V
O
X
#
System parameters
[SP21]Current limit SPL L1/L2/L3
0.0
A
O
X
#
System parameters [SP22]Device name
O
X
#