![hotset hotcontrol cDT+ Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/hotset/hotcontrol-cdt/hotcontrol-cdt_start-up-service-and-operation-manual_2170222081.webp)
Hotset GmbH
79
Start-up-, Service- and Operation Manual hotcontrol cDT+
Rev. 1.00.05
Subject to technical changes
13.3 Sensor alarm TCs
13.4 Potential error Pot
TCs
Under a sensor alarm, we understand the case, where
a) the sensor wire is squeezed somewhere in between sen-
sor and controller and a short circuit exists
b) the sensor is not in the intended position (removed or is
swapped with another).
How it works
Through the defect in the cable to the controller a low tem-
perature value is forecast. The actual temperature is much
higher than the measured temperature.
If there is no rise in temperature measured in a zone type
(considered nozzles and manifold) in a dependent time, a
sensor alarm is displayed to the user. To prevent damage
to the appropriate zone, the heating is turned OFF.
A sensor alarm can be faulty, and that is when the heat out-
put of the zone is too small. It shows an identical error im-
age.
What good is it
The sensor alarm provides the user with a specific indica-
tion of the error in the hot runner or the wiring, and provides
the ability to pinpoint errors quickly and correct it.
Remedy
Reason
Trouble Shooting
Short circuit in sensor
circuit
Check the connected sensors
Check connecting cable of hot runner controller
Sensor position
Check position
Pot
On the sensor input a too high voltage is detected.
How it works
Error is detected by the hardware on the HTC 06/15 Heating
Thermocouple Card.
What good is it
For protection all zones get de-energized (relay on HTC-
Card OFF), also the zones on the other HTC-Cards, due to
the voltage may come from any zone.
Remedy
Reason
Trouble Shooting
Error on tool
Check sensor input
Check grounding/sensor