68
[b] KM-80C-HC
1) Unplug the icemaker.
2) Remove the top panel, and unscrew the rear panel.
3) Disconnect the connector of the float switch lead (gray).
4) The float switch is located behind the pump motor. Pinch the arrowed part (1) and
pull it diagonally forward (2) to unhook the float switch.
5) Remove the screw securing the float switch to the bracket.
6)
Attach the new float switch to the rail of the bracket. Secure them with the screw by
fitting the round end of the slot to the screw hole.
②
①
③
②
③
Pump Motor
Float Switch
Hook (A)
Hook (B)
Float Switch
Bracket
Screw
Pinch
Pull
Rail
Round end of slot
* Secure here with
screw
When fitted properly, top ends
of bracket and float switch
become flush with each other
Screw