23
59 Forced drain
When "drn" is selected, unit de-energizes
every component, drain ("drn"), and shuts
down ("oFF"). If reset button is pressed
during drain cycle, unit shuts down.
–
drn
–
60 Notice (e.g.
maintenance)
Notice code “n99” appears after set period of
time.
6000
hrs
0 hrs
(none) 100 hrs
64
Compressor run
time reset
Reset compressor run time counting
(maintenance mode).
–
res
–
65
LED run time
reset
Reset LED run time counting (maintenance
mode).
–
res
–
66
Number of
chemical doses
reset
Reset number of chemical doses for fully
automated cleaning kit (maintenance mode).
–
res
–
67
Auto-reset error
check
When “err” is selected, display shows
ongoing auto-reset errors.
–
err
–
69 Low water shut
down
If low water is detected in fill cycle, unit shuts
down for water leak error.
ON
OFF
–
Err Error history
Show last ten errors.
–
res
–
Fre Freeze cycle time Show freeze cycle time (min) for last ten
cycles.
–
res
–
HAr Harvest cycle
time
Show harvest cycle time (min) for last ten
cycles.
–
res
–
EVA Evaporator outlet
temperature
Show evaporator outlet thermistor
temperature.
–
res
–
Con Condenser
temperature
Show condenser outlet thermistor
temperature.
–
res
–
FCt
Number of freeze
cycles
Show number of freeze cycles.
–
res
–
ut
UV-LED
irradiation time
Show UV-LED irradiation time.
–
res
–
Sct Total number of
chemical doses
Show total number of chemical doses for fully
automated cleaning kit.
–
res
–
CCt Compressor run
time
Show compressor run time (hrs).
–
res
–
VEr
Software version Show software version.
–
res
–
Cod
Model code
change
Change model code.
–
res
–