29
E91
Pump motor
Locked
Replace
Pump motor discharge
hose
Disconnected
Reconnect
Hot gas valve
Closing failure
Replace
Hot gas valve relay
Bad contacts
Replace
E98
Drain valve
Opening failure
Replace
Pump motor
Locked
Replace
Low RPM
Replace motor or control board
Float switch
Float sticking
Descale
Bad contacts
Replace
Water valve
Opening failure
Clean or replace
Water valve relay
Coil circuit open
Replace
n32
LED
Irradiation failure
Replace
n33
Tube pump motor
Broken
Replace
Fully automated
cleaning hose
Disconnected
Reconnect
n70
Water circuit
Low water
Check water tap
Low water pressure
Adjust
Water valve
Closing failure
Clean or replace
Water valve relay
Bad contacts
Replace
Water tank
Disconnected
Reconnect
Broken
Replace
Float switch
Float sticking
Descale
Bad contacts
Replace
n92
Air filter
Clogged
Clean
Fan motor
Locked
Replace
Broken fan
Replace fan
Fan motor relay
Coil circuit open
Replace
n93
Chemical pack
Set number of times
exceeded
Replace
n99
Control board
Set time exceeded
Press reset button after
maintenance
Starting failure
Replace control board
4. THERMISTOR
A thermistor (semiconductor) is used as a harvest control sensor and anti-slush sensor.
The resistance varies depending on the suction line temperatures.
During the harvest cycle, the thermistor detects the evaporator outlet temperature
and starts the harvest completion delay timer (Setting 1: 0 to 210 seconds) when the
temperature reaches the harvest completion temperature (Setting 16: 6 to 12°C).
During the freeze cycle, the thermistor detects the evaporator outlet temperature and
momentarily stops the pump motor to prevent slushing in accordance with the anti-slush
control (Setting 12: 0 to 2) and the slush ice control (Setting 62: -5 to 20°C).
No adjustment is required. If necessary, check for resistance between thermistor leads,
and visually check the thermistor mounting, located at the evaporator outlet.