34
F-800MWF-C
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION
Temp. (°F)
PER 24 HR.
70
670
(304)
650
(295)
640
(290)
80
625
(284)
615
(279)
605
(274)
90
590
(268)
590
(268)
570
(258)
lbs./day ( kg/day)
100
560
(253)
550
(249)
505
(229)
APPROXIMATE ELECTRIC
70
1140
--
1155
--
1155
--
CONSUMPTION
80
1140
--
1155
--
1155
--
90
1140
--
1155
--
1155
--
watts
100
1140
--
1155
--
1155
--
APPROXIMATE WATER
70
398
(1.81)
580
(2.63)
945
(4.30)
CONSUMPTION PER 24 HR.
80
415
(1.89)
605
(2.75)
992
(4.51)
(TOTAL)
90
431
(1.96)
624
(2.84)
1042
(4.74)
gal. / day (l/day)
100
448
(2.04)
661
(3.00)
1159
(5.27)
EVAPORATOR OUTLET TEMP.
70
21
(-6)
22
(-6)
21
(-6)
°F (°C)
80
22
(-6)
22
(-6)
22
(-6)
90
21
(-6)
23
(-5)
22
(-6)
100
23
(-5)
23
(-5)
23
(-5)
HEAD PRESSURE
70
265
(18.6)
267
(18.8)
266
(18.7)
80
267
(18.8)
266
(18.7)
265
(18.7)
90
266
(18.7)
266
(18.7)
265
(18.7)
PSIG (kg/cm²G)
100
267
(18.8)
269
(18.9)
268
(18.8)
SUCTION PRESSURE
70
37
(2.6)
37
(2.6)
37
(2.6)
PSIG (kg/cm²G)
80
38
(2.6)
37
(2.6)
38
(2.6)
90
38
(2.6)
38
(2.6)
38
(2.7)
100
39
(2.7)
39
(2.7)
39
(2.7)
WATER FLOW FOR CONDENSER
46 gal/h (AT 90°F /WT 70°F)
PRESSURE DROP OF COOLING WATER LINE
Less than 7 PSIG
HEAT OF REJECTION FROM CONDENSER
6270 BTU/h (AT 90°F /WT 70°F)
HEAT OF REJECTION FROM COMPRESSOR
1290 BTU/h (AT 90°F /WT 70°F)
Note: The data without *marks should be used for reference.
50
70
90
We reserve the right to make changes in specifications and design without prior notice.
Содержание F-800MAF
Страница 9: ...9 2 CONDENSER UNIT URC 6F ...
Страница 15: ...15 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAF C ...
Страница 16: ...16 F 800MWF C ...
Страница 17: ...17 2 WIRING DIAGRAMS F 800MAF C F 800MWF C ...
Страница 19: ...19 b When Reservoir has been filled Gear Motor starts immediately ...
Страница 20: ...20 c Compressor starts about 60 sec after Gear Motor starts ...
Страница 21: ...21 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously ...
Страница 22: ...22 e Low Water Except Water cooled Model ...
Страница 24: ...24 g When Flush Switch is moved to FLUSH position Flush Water Valve opens and flushes Reservoir and Evaporator ...
Страница 25: ...25 h When Flush Timer operates for 15 min every 12 hours ...