background image

 

IF USING PILLOW PACKS

 

1.  Discard any open or damaged packs  

2.  Inspect the containers used for steeping and or dispensing the coffee, including steeping baskets or                                          

toddy nylon filter, for cleanliness 

3.   If using Kegs, inspect,  clean and sanitize kegs 

4.  Clean and sanitize the containers and filters following the weekly cleaning instructions                                                

(see attached guide) 

5.   Once the container/dispenser if clean prepare coffee for steeping (12 hours)                                                                     

(for use in dispenser or kegs) 

 

IF USING BAG-IN-BOX (BIB) 

1.  Discard any open or partially used  product 

2.  Check expiration dates–discard BIBs that are past date. 

3.  Make sure that there is chilled product ready.   
 

IF USING ARIA, KEGERATOR OR BROOD COLD BREW UNITS: 

1.  Open the unit and verify there is no product in the unit ( Bag in Box or keg with coffee)                                                 

Make sure kegs are clean and sanitized. 

 

2.  If the unit is unplugged check the pump switch is in the off position. (Aria and Kegerator the                                         

pump switch is inside the unit. The Brood unit pump switch is on the front of the unit)                                                         

Plug in the unit keeping the pump switch in the OFF position. (the Aria requires 

two

110v outlets) 

     The refrigeration unit should chill to 38-40°F 

 

3.  Inspect the dispense lines for black buildup or spots.  

A.  If you detect black residue:  

DO NOT USE THE UNIT

.  

The lines must be replaced                                                        

Call illy Caffe Technical service to schedule a service call.    

B.  If you do not detect black buildup; Follow the weekly cleaning and sanitizing protocol and                                     

soak the tap (see attached guides)    

   

4. 

Once the system and tap are clean and coffee is steeped or Bag in Box is chilled:                                                    

Do not serve product  unless it is cold  

 

A.  Put steeped coffee into the keg, and connect it to the Aria or Kegerator.  

OR

 

B.  Connect  the pre-chilled Bag in Box    

 

5.  Turn the pump switch on to the unit. Put a container under the tap. Set the tap on still brew.                                

Pull down on the tap and purge air from the system.                                                      

 

6.  Pour a glass of still brew and a glass of Aria to taste.  

      

 

If  you experience any technical problems, please contact Illy Caffe Technical Service  at 1(800) 872-4559 to 
initiate a service call. One of our team members will contact you to troubleshoot  the issue

 

RESTART: COLD BREW 

©2020 ICNA Inc. This manual/document and its contents are the property of illy caffè North America Inc. and its parent company, Illycaffè S.p.A 

This information is not to be distributed, modified or copied without express written permission of Illycaffè.  

 

Check that you have all the appropriate supplies: Cleaning Bottle, Urnex 1-2 Cold Brew ®cleaner and sanitizer. 

Содержание COLD BREW ARIA

Страница 1: ...0 F 3 Inspect the dispense lines for black buildup or spots A If you detect black residue DO NOT USE THE UNIT The lines must be replaced Call illy Caffe Technical service to schedule a service call B...

Страница 2: ...ld Cleaner See Chart 2 Place the basket insert into the solution or Toddy Nylon filter 3 Run 1 liter of water through the tap and Let sit for 15 minutes 4 After 15 minutes empty the remaining solution...

Страница 3: ...e dispense line to the OUT stem of the keg and place the keg back into the unit 6 Place a container under the tap on the door To purge air from the system open the tap and turn ON the pump When the co...

Страница 4: ...box 7 Place the bag in box stand inside unit with the taller open side on the right Turn bag in box upside down with the black ball lock connector on the dispense line in the downward position towards...

Страница 5: ...e into the cardboard opening On the top of the box always record the date connected and expiration date Maximum 5 days after opening Connect the dispense line black ball connector to nozzle on the box...

Страница 6: ...iner and let it soak for 15 minutes 5 6 CLEANING Urnex Clearly Cold Solution SANITIZING Urnex Complete Caf Solution Item US3560 Remove and rinse the keg and the grey air intake valve Re ll keg with 2...

Страница 7: ...elease any residual pressure from the unit 4 Disconnect the black dispense line out from the keg or the BIB Bag in Box 5 Attach the black connector to the stem on the cleaning bottle and ensure it is...

Страница 8: ...le Once attached pull up to ensure it is secured close the door of the unit with the bottle outside of the door and turn on Place a container under the tap spout Run the solution through the system fo...

Страница 9: ...2 Check if there is coffee in the container Re ll if necessary 3 Check for proper connection of intake black ball lock on the dispense line to the OUT stem of the keg When nished turn the pump OFF and...

Отзывы: