49
13) Recover the refrigerant and store it in an approved container, if required by an applicable
law.
IMPORTANT
Always install a new Drier every time the sealed refrigeration system is
opened. Do not replace the Drier until after all other repairs or replacement
have been made.
14) Remove the Bulb of the Expansion Valve.
15) Disconnect the brazing-connections of the Expansion Valve and the Copper Tube - Low
Side from the Evaporator, using brazing equipment.
16) Remove the two Truss Head Machine Screws and the Strap securing the Evaporator.
17) Disconnect the three Hoses from the Evaporator.
18) Remove the four Socket Head Cap Screws securing the Evaporator with the Bearing-
Lower.
19) Lift off the Evaporator.
BEARING-LOWER AND MECHANICAL SEAL
20) The Mechanical Seal consists of two parts. One moves along with the Auger, and the
other is fixed on the Bearing-Lower. If the contact surfaces of these two parts are worn
or scratched, the Mechanical Seal may cause water leaks and should be replaced.
21) Remove the O-ring on the Bearing-Lower.
22) Remove the four Bolts and the Bearing-Lower from the Gear Motor. Replace the
Bearing inside the Bearing-Lower, if it exceeds the wear tolerance of 0.02" or is
scratched.
Note: Replacing the Bearing requires a bearing press adaptor. If it is not available,
replace the whole Bearing-Lower.
GEAR MOTOR
23) Remove the Coupling-Spline on the Gear Motor Shaft.
24) Remove the Barrier on the top of the Gear Motor.
Содержание F-800MAF
Страница 9: ...9 2 CONDENSER UNIT URC 6F ...
Страница 15: ...15 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAF C ...
Страница 16: ...16 F 800MWF C ...
Страница 17: ...17 2 WIRING DIAGRAMS F 800MAF C F 800MWF C ...
Страница 19: ...19 b When Reservoir has been filled Gear Motor starts immediately ...
Страница 20: ...20 c Compressor starts about 60 sec after Gear Motor starts ...
Страница 21: ...21 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously ...
Страница 22: ...22 e Low Water Except Water cooled Model ...
Страница 24: ...24 g When Flush Switch is moved to FLUSH position Flush Water Valve opens and flushes Reservoir and Evaporator ...
Страница 25: ...25 h When Flush Timer operates for 15 min every 12 hours ...