5
I. SPECIFICATION
1. ICEMAKER
F-800MAF
AC SUPPLY VOLTAGE
115-120/60/1
COMPRESSOR
120 V
9.2 RLA
60 LRA
GEAR MOTOR
120 V
1.6 FLA
1/6 HP
FAN MOTOR
115 V
0.85FLA
1/15 HP
OTHER
120 V
0.03A
MAXIMUM FUSE SIZE
20 A
MAX. HACR BREAKER (USA ONLY)
20 A
MAX. CIRC. BREAKER (CANADA ONLY)
20 A
MINIMUM CIRCUIT AMPACITY
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*800 (363)
765 (347)
735 (334)
Reference without *marks
80
710 (321)
680 (309)
655 (297)
90
630 (286)
*615 (279)
585 (264)
100
560 (254)
540 (245)
*505 (229)
SHAPE OF ICE
Flake
ICE QUALITY
Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1205 (4.7)
1175 (3.5)
POTABLE WATER
74 (12)
96 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH)
22" x 27-3/8" x 25-1/4" (560 x 695 x 642mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 172 lbs. ( 78 kg ), Shipping 198 lbs. ( 90 kg )
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
ICE MAKING SYSTEM
Auger type
HARVESTING SYSTEM
Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING WATER CONTROL
Float Switch
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR
Hermetic, Model RS55-C1E-PAA
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Copper Tube on Cylinder
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
1 lb.10oz.
(750g)
DESIGN PRESSURE
High 427 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-off Relay
COMPRESSOR PROTECTION
Auto-reset Overload Protector
GEAR MOTOR PROTECTION
Manual reset Circuit Breaker or Fuse
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch and Timer
ACCESSORIES -SUPPLIED
Spare Fuse
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 - 100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
DRAWING NO. (DIMENSION)
3A0985
We reserve the right to make changes in specifications and design without prior notice.
Содержание F-800MAF
Страница 9: ...9 2 CONDENSER UNIT URC 6F ...
Страница 15: ...15 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERATION CIRCUIT F 800MAF C ...
Страница 16: ...16 F 800MWF C ...
Страница 17: ...17 2 WIRING DIAGRAMS F 800MAF C F 800MWF C ...
Страница 19: ...19 b When Reservoir has been filled Gear Motor starts immediately ...
Страница 20: ...20 c Compressor starts about 60 sec after Gear Motor starts ...
Страница 21: ...21 d Bin Control operates and about 6 sec later Compressor and Gear Motor stop simultaneously ...
Страница 22: ...22 e Low Water Except Water cooled Model ...
Страница 24: ...24 g When Flush Switch is moved to FLUSH position Flush Water Valve opens and flushes Reservoir and Evaporator ...
Страница 25: ...25 h When Flush Timer operates for 15 min every 12 hours ...