Flow meter test
¾
To test the flow meter, the test adapter set
can be ordered from HORSCH.
1.
Disconnect the hose union to the flow meter
on the middle section.
2.
Connect the first hose of the test adapter set
to the flow meter. Connect the second hose
of the test adapter set to the dismantled hose
on the flow meter.
3. Connect the two other ends of the hoses of
the test adapter set to the test device.
4. To perform the test, circulation must be acti-
vated on the terminal.
5. Deactivate circulation on the terminal again
after the test has been completed.
6. Uncouple both hoses of the test adapter set
on the test device and on the sprayer.
7. Establish the hose connection again on
the flow meter on the middle section of the
machine. Ensure a correct and watertight
connection!