4.5 Setting the Parameterbyte for the Serial Interface
see appendix
serial interface
4.6 Setting the Modebyte for the Serial Interface
see appendix
serial interface
4.7 Show Points of Changeover, Radio Bit, DCF77-Sim and Evaluation Mode
Under point 8 of the main menu the programmed points of change over can be checked.
Attention:
New values will be calculated by the clock at the next minute change. In case of set-
ting new values this function should not be used before the next minute change.
Additionally the information about the time out of the radio bit and the DCF77-Simulation are
made.
The following display appears:
change over to daylight saving time: month 03, hour 02
time
02:00:00 day of week 07 date 29.03.96 worked out
change over to standard time: month 10, hour 03
time
03:00:00 day of week 07 date 23.10.96 active
time out radio bit after 2 minutes
time out DCF77-simulation after 2 minutes
DCF77-simulation length of Hi-Bit 200 milliseconds
DCF77-simulation length of Lo-Bit 100 milliseconds
You must wait at least one minute until the new change over points have
been calculated by the radio controlled clock !
press any key...
here you can control the change over date and it’s status. Also you can control the date, the time
and the day of the week.
Please note :
During the output of the points of changeover the time data are invisi-
ble for about 5 seconds. Synchronisation processes running in the
background may contain wrong data.
4.8 Activate Reset of the Clock Board
Menu item 9 of the service programme can be used to activate a reset in the clock. All previ-
ously altered settings in the clock remain.
Please note :
Errors may occur during the synchronisation process
(FUNKINST.EXE, HOPFTIME.EXE or other clock drivers already ac-
tive) because for about 2 seconds after a reset the I/O range of the
clock board is faded out (all data positions $FF).