GPS PC-board 6038
hopf
hopf
Elektronik
version 03.01
page 15
The address range
(
base address to base a$0F) contains the time and date informa-
tion as BCD or binary values compatible with the clock board 6036. If you are using the
hopf
hopf
__
clock drivers
"FUNKINST"
or.
"HOPFTIME"
you can operate without the command line
parameters
"u"
and
"m"
, because the according time information appears at base address to
base a$0F.
•
mode 2
time information local time
•
mode 3
time information UTC time
•
mode 4
time information local time
(
standard time only)
example :
If you intend to synchronise your computer with UTC the parameter
"u"
can
be omitted if the board is switched over to mode 3.
The address range (base a $30 to base a $3F) is compatible with the clock
board 6036 in all modes.
After selecting menu item 4 in the service programme the following menu appears:
Attention: Change output mode!
First read the paragraph "set output mode" in your manual of the clock board
before changing the settings.
key [ 1 ] mode 1 -->
compatible with clock board 6036 local time,
UTC, local time (standard time only)
key [ 2 ] mode 2 -->
local time with position data and status in
formation
key [ 3 ] mode 3 -->
UTC (Universal Time Coordinated),
with position data and status information
key [ 4 ] mode 4 -->
Local Time (standard time only)
position- and status information
your choice 1/2/3/4, or Esc for end !
Esc for end !
After the selection of the mode you will be asked to enter the time base for the DCF77-
simulation integrated in the board. This signal can be used for the synchronisation of other
DCF77 receivers (in TTL level, active low). The output is made at the 9 pole SUB D female con-
nector (please see the description of the board panel).
Here comes a translation.
DCF77-Simulation
key [ 1 ] local time as time base for the DCF77-simulation
key [ 2 ] UTC as base for the DCF77-simulation
Esc for end !
When the time base is selected the data are transferred to the clock board where it is stored in a
fail-safe memory there.