GPS PC-board 6038
hopf
hopf
Elektronik
version 03.01
page 17
5 LED on the Front Panel
The synchronisation status can also be checked by means of the LED on the front panel.
If the LED flashes at second intervals it means:
the clock is in crystal operation
If the LED is lit permanently:
radio operation
6 Output pulses
The following pulses are available at the 9-pole SUB-D connector:
second pulse
length
100 milliseconds
minute pulse
length
1 second
hour pulse
length
1 second
24 h pulse
length
1 second
the signals are delivered in TTL-Level active low (Connection diagram See appendix).
7 Files on the Disc
The supplied system disc for the clock board contains the following files:
•
DOS_DRV\Funkinst.exe
DOS synchronisation process
•
WIN31x\Hopftime.exe
Windows 3.x synchronisation process
•
WIN95\SyncProc.exe
Windows 95/98 synchronisation process
•
WINNT\HopfServ.exe
Windows NT synchronisation process
•
SERVICE_D.EXE
service programme for diagnostic purposes (german)
•
SERVICE_E.EXE
service programme for diagnostic purposes (english)
•
IRQEXAPL.PAS
example programme to make an IRQ