background image

Installation Instructions for the Digital Clock Series C 210

 

Page 1 of 2 

C

Switching on the clock 

Switch on the clock by means of the slide switch on the reverse side. All segments are now visible in the display for a short moment.  The 
clock switches automatically to radio reception (standard setting) for a maximum of 20 minutes. A constant blinking – in seconds - of the 
radio waves at the radio tower symbol (top right in the display) indicates the reception of radio impulses. The radio tower remains 
visible in case of 

satisfying reception

, in case of poor reception it disappears. Thereby you can always control the quality of the 

radio signal in each individual location. The clock requires 3 minutes of proper reception to indicate time and date. 

 

What to do in case of radio interference 

Sources of interference such as television, monitors, computers, metal walls or buildings with reinforced concrete walls may deteriorate 
or even prevent reception. Check the receiving quality by watching the radio tower symbol. If the symbol disappears frequently, change 
the location.  Put the clock on your window sill where you will have the best reception. 

Avoid moving the clock during the reception 

process! 

 

In case of durable interference, there are four options to solve the problem:  

1) 

Install the clock at another point in order to obtain best receiving results. 

2) 

Change the clock to quartz-controlled mode. (see: Setting of the Operation Mode) 

3) 

Keep the clock in the radio mode but set the current time manually. At 2 and 3 a.m. for 20 minutes each, the clock will attempt 
synchronisation with radio operation. Sources of interference such as computers and neon lamps are disconnected at night 
enabling improved reception. Should these attempts however not be successful, the life of the battery will be reduced due to 
longer receiving hours at night.  

4) 

An  external  aerial  is  optionally  available.  Connect  this  aerial  to  the  clock  and  lay  the  aerial  cable  to  a  point  providing  improved 
receiving  quality.  If  the  cable  is  not  long  enough,  it  can  be  extended  up  to  max.  30  m.  We  recommend  the  cable: 

I-Y(ST)Y 

2x2x0.6.

  This requires that you lay the shielding and the free lead to the 0-volt phase of the cable and connect it to the aerial. The 

colour code of the aerial cable is as follows:       White = +3V, green = data, brown = GND 

Setting of the Operation Mode

 

Select the operation mode 

by pressing and holding the button T1 or T2

 during the switch-on phase. Keep the relevant button pressed, 

switch on the clock and then release the button.

 

T1

 activates the quartz operation mode and deactivates the reception of the DCF-77 radio signal. Whereas 

T2

 activates the DCF mode 

and switches the clock to radio operation. 

The mode selected last will be saved and automatically activated when switching on the 

clock again.

 

Manual Setting of Time and Date

 

By pressing the 

T1 

button, when the clock is switched on, you get to the time and date setting, as well as to the temperature readout. 

Preferably proceed as shown in the example below. By actuating the 

T2 

button for entering hour 

 minute 

 day 

 month 

 

temperature 

 seconds (AC 150 only) you can make changes in the sequence as indicated. Press the 

T3

 button for setting the desired 

values. Finally save and terminate the settings by pressing the 

T1 

button and the clock shows the changed values. 

 

Setting Example  

Press 

T1

 once and set the hour by pressing 

T3

 Press 

T1

 once and set the minute by pressing 

T3

 Press 

T1

 once and set the day 

by pressing 

T3

 Press 

T2

 once and set the day by pressing 

T3

 Press 

T2

 once 

and set the month by pressing 

T3

  

Press 

T2

 once and set the year by pressing 

T3.

 

 Press 

T2 

once and a thermometer is 

shown in the display. Now you can set 

the temperature indication to three different modes by means of the 

T3 

button: 

 

Caution: The temperature sensor is optional equipment. Without the sensor the clock shows only –0°C. 

 

A

  

the 

temperature alternates with the date display

, this means, the temperature (for 4 seconds) alternating with the   

date display (for 6 seconds), will be depicted in the bottom line. 

 

 

fixed temperature display , this means no date is shown 

 

No symbol

  

“temperature readout off”, thus permanent date display 

 

Press 

T2

 once and an 

A

 is shown in the display:

 

And a 

blinking figure

 between 0 and 3. Here you can set the seconds readout  (for 

clock type AC 150 only)  again with the 

T3 

button. The values are indicated below: 

 

 
 
 
 
 
 
Now you have finished the settings in this menu, and by pressing 

T2

 you return to the beginning of the cycle, i.e. for setting the hour.  To 

terminate the settings, simply press the 

T1

 button, while the seconds are automatically set to zero and from now on start counting. The 

clock returns to the normal display mode and the adjustments you have just made are saved.

 

 

Value

 

Mode 

Minute marks light up or extinguish 

Seconds readout off, all marks light up 

Minute marks always light up 

Only the mark of the actual second fades out 

Отзывы: