background image

Installation Instructions for the Digital Clock Series C 210

 

Page 2 of 2 

Setting of the Time Zone 

For  the  countries  Germany,  Austria,  Switzerland,  France,  Benelux,  the  time  is  set  in  the  factory  to  +1  hour  to  the  world  time  (UTC  = 
Coordinated Universal Time) 

and needs to be changed only in case of deviating from this time, for example UK

. For this, an offset 

can be set, which adds to or deducts from the radio time received (corresponding to the world time). Thereby you have the option to use 
the  clock  as  part  of  a  world  clock  or  use  it  in  adjacent  time  zones,  where  the  DCF-//  radio  waves  from  Frankfurt  are  received.For  this 
purpose, press the 

T2

 button in the normal mode of the clock, 

“Of”

 is shown in the display and the set offset in hours (the first two digits) 

and in minutes (the last two digits).  The offset can be set in a range of +/- 12 hours with the buttons 

T1

 for 

+30 minutes

 and 

T3

 

for -30 

minutes

.    By  pressing  the  button 

T2

  again,  the  setting  is  terminated  and  the  new  value  is  saved.  For  the  operation  in  the  above 

mentioned time zones, ‘+0100’ is preset here.

 

Setting of the Summer/Winter Time Parameter 

The settings of summer and winter time comply with the legal regulations, but may be altered in case these times change. By actuating 
the 

T3

 button in the normal mode of the clock, you reach the setting mode for the summer time. The clock now indicates 

‘So’

: for the 

summer time and either 

‘On’

 (automatic switching for summer/winter time or 

‘Of

 (no automatic switching). The button 

T3

 serves to switch 

from 

‘On’ to ‘Of’

 and vice versa. In the 

‘Of’

 setting, the clock returns to the normal mode after pressing the 

T2

 button. If 

‘On’

 is selected, 

the start and end of the summer time can be set after the 

T2

 button has been pressed or by pressing 

T2

 again, the standard settings can 

be maintained.  To achieve this, the 

T2 

button is to be pressed several times (4x) until the normal display mode is shown.

 

Setting of the Start/End of the Summer Time 

The clock change is always effected on a Sunday, i.e. two months and the respective Sundays have to be adjusted. First, the data for the 
start of the summer time are queried. The clock indicates the month of the start as figure: the month blinks and can be set in a range 
from  1  to  12  with  the 

T3 

button.  By  actuating 

T2

  you  select  the  respective  Sunday:  With  the 

T3

  button  you  can  choose  between  the 

figures from 

1 to 4

 and 

‘L’.

 The figures indicate the Sunday, from the 

1

st

  to the 

4

th

, while 

‘L

’ stands for the last Sunday of the month. By 

pressing 

T2 

you terminate the input of the start data. Now the data for the end of the summer time is to be adjusted in the same manner. 

After completing the input, press 

T2

 and the clock is reset in the normal mode and the data is saved.

 The standard factory setting for 

Germany is the last Sunday in March for the start and the last Sunday in October for the end.

 

Secondary Clock Input 

In case option ‘N’ was included in the order for the clock, a pole changing impulse of the master clock with a voltage ranging from 12 to 
60 volt may be applied to the connecting field via the terminals 1 and 2. 

External connector for DCF radio reception: 

The DCF antenna can be connected on the reverse side of the clock. For this purpose, the respective DIP switches have to be adjusted 
as defined in the table below. Radio reception is transmitted in frequency band 77.5 KHz.  

Connecting of an External Temperature Sensor 

An  external  sensor  may  be  connected  on  the  reverse  side  of  the  clock  to  be  used  instead  of  an  internal  sensor.  In  such  a  case,  the 
internal sensor will be deactivated.

 

External Power Source 

An external direct voltage source may be supplied to the clock via the terminals 11 and 12. The voltage should not exceed 9 volt and not 
fall below 6.5 volt. 

 

Setting of the DIP Switch on the Reverse Side 

DIP-Switch 

ON 

OFF 

1,2 

Internal DCF aerial activated 

External DCF aerial activated 

3,4,5 

Language selection for day display, see separate scheme 

DCF signal inverted 

DCF signal normal 

Inverse date display (MM/DD) 

Date display normal (DD/MM) 

Suppress left-hand zeros for hours and 

Depict left-hand zeros 

Language Settings for the Days of the Week 

DIP3 

DIP4 

DIP5 

Language 

Off 

Off 

Off 

German 

On 

Off 

Off 

English 

Off 

On 

Off 

Dutch 

On 

On 

Off 

French 

Off 

Off 

On 

Spanish 

 
 

Display of 

bold type

 correspond with our factory settings 

 
 
Should you have any questions when installing the clock, please do not hesitate to contact us. 

 

Valentin Elektronik GmbH   Tel. +49 0(202) / 264 17 22 

1

2

3

4

5

6

7

8

ON

DIP-Switches

ON - OFF

T1

T2

T3

Connecting field

1

12

B

a

c

k

s

id

e

Отзывы: