EC Sensor Cartridge and Cell Replacement
Caution:
For toxic ells, remove the shorting clip from the bottom of the cell prior to installation.
No shorting clip is provided with oxygen cells..
CAUTION
!
The serviceable sensor allows replacement of the cell inside the
sensor. The cell must be replaced with one of the same type as
the original.
When replacing oxygen (O
2
) sensor cells, the initial warm-up time
is between 10 and 15 minutes. This warm-up is required only
after sensor cell replacement.
Replacing the Sensor Cell
To replace the cell follow this procedure:
1. Unscrew the weatherproof cover, loosen the sensor
retainer locking screw, and unscrew the sensor retainer.
2. Remove the old sensor by pulling without twisting.
3. Unscrew the sensor cap.
4. Remove the old cell by pulling without twisting.
5. Verify that the new cell is the same type as the old one.
6. Plug the new cell into the sensor. Align the sensor pins
with the connector holes in the PCB.
7.
Refit the sensor into the transmitter ensuring that the pins
are fully aligned before gently pushing it fully home.
8. Sensor warm-up will begin and the display will alternate
between two screens: “Fault 151” and “WARM.”
Figure 226. Sensor screens during warmup
9. Follow the procedure to accept the new sensor in the
section.
10. Recalibrate the sensor following the procedures in the
Span Calibration for EC/mV Sensors, and Searchpoint Optima
section.
Transmitter
Sensor Retainer &
Locking Screw
Old Sensor
3
2
1
4
5
6
New Sensor
EC Sensor Removal
Sensor Cap
Old cell
New cell
Sensor Cell Replacement
Figure 227. XNX EC sensor and cell replacement
Содержание XNX-AM Series
Страница 2: ...This page is intentionally left blank ...
Страница 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Страница 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Страница 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Страница 31: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 29 Installation and Operation ...
Страница 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Страница 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Страница 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Страница 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Страница 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Страница 177: ...XNX Universal Transmitter Control Drawings 175 ...
Страница 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Страница 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Страница 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Страница 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Страница 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...
Страница 206: ...This page is intentionally left blank ...