4
. Operations and Monitoring
4.2. Parameter Setting
44
Isolated Thermocouple Input Module TC4S User's Guide
R200
Honeywell
September 2010
Flag Setting
Flag
Description
Address Number
PUT/GET
Error
a) If there is no special
module installed on
specified slot.
b) If PUT/GET
instruction is not
completed correctly.
F0015 ~ F0022
PUT
•
This instruction is used to write the data in special module with memory.
•
It writes N word data from address specified in S2, in specified special module’s
memory (specified in S) in sl (special module’s slot number).
•
If there is no special module specified in sl (special module’s slot number), or PUT
instruction is not completed correctly, applicable position bit of PUT/GET Error
Flag, F0015~F0022 (WORD) will be set.