5
. Internal Memory
5.1. Configuration of internal memory
62
Isolated Thermocouple Input Module TC4S User's Guide
R200
Honeywell
September 2010
Operation parameter setting area (use of PUT/PUTP)
Memory
Address
Description
R/W
Remarks
Dec.
Hex.
0
0H
Designate a channel to use
R/W
PUT/GET
1
1H
Set sensor type of CH 0
R/W
PUT/GET
2
2H
Set sensor type of CH 1
3
3H
Set sensor type of CH 2
4
4H
Set sensor type of CH 3
5
5H
Designate temperature metric system
R/W
PUT/GET
6
6H
Set CH 0 filter value
R/W
PUT/GET
7
7H
Set CH 1 filter value
8
8H
Set CH 2 filter value
9
9H
Set CH 3 filter value
10
AH
Set averaging method of CH 0
R/W
PUT/GET
11
BH
Set averaging method of CH 1
12
CH
Set averaging method of CH 2
13
DH
Set averaging method of CH 3
14
EH
Set mean value of CH 0
R/W
PUT/GET
15
FH
Set mean value of CH 1
16
10H
Set mean value of CH 2
17
11H
Set mean value of CH 3
18
12H
Designate scaling type
R/W
PUT/GET
19
13H
Set min. value of CH 0 scaling range
R/W
PUT/GET
20
14H
Set max. value of CH 0 scaling range
21
15H
Set min. value of CH 1 scaling range
22
16H
Set max. value of CH 1 scaling range
Содержание TC4S
Страница 114: ...7 Troubleshooting 7 4 Error code 114 Isolated Thermocouple Input Module TC4S User s Guide R200 Honeywell September 2010 ...
Страница 126: ...8 Appendix 8 3 Dimension 126 Isolated Thermocouple Input Module TC4S User s Guide R200 Honeywell September 2010 ...
Страница 127: ...8 Appendix 8 3 Dimension R200 Isolated Thermocouple Input Module TC4S User s Guide 127 September 2010 Honeywell ...
Страница 128: ...Honeywell Process Solutions 1860 W Rose Garden Lane Phoenix AZ 85027 USA ...