Maintenance
4.7
Resetting Alarms and Faults
The default setting of each alarm is non-latching type. If you want to
have a latching type alarm, change the alarm mode using the
Sensepoint mobile app.
1. Pair with the target detector and tap
Settings
.
2. Tap the edit button
at the upper right side of the screen.
3. Scroll down to
Alarm latching
and choose
Latching
.
4. Scroll down to the bottom of the page and tap
Apply Settings
to
save the change.
When there are latched gas alarm or faults, reset them using either of
these two methods:
• Use the mobile app to pair with the detector, and tap
Maintenance
>
Reset Alarm
.
• Alternatively, press the UP or DOWN button shortly.
This will reset latched alarms and faults, and initiate a self diagnostics
to make sure there is no warning or fault in the detector.