l
System expansion is available via V-Plex and IB2 bus:
o
Zone expansion is possible via V-Plex sensors or zone expanders
connected to the IB2 bus.
o
Output expansion is possible via V-Plex devices or relay modules
connected to the IB2 bus.
2.2.3
IB2 Bus for Expansion Modules
The Intellibus 2 (IB2) bus is the main 4-wire communication bus on which
keypads, relay modules, zone expanders, and other peripheral devices are
connected to the system. IB2 characteristics include:
l
Guaranteed performance of up to 46 IB2 bus devices per bus.
l
Provides free wiring topology (chain, star, or spur configuration).
l
Does not require end-of-line resistors.
l
Unique device IDs embedded within each device for easy enrolling on the
system.
l
Each IB2 bus device is individually supervised.
l
Easy device swapping feature from MAXPRO Cloud.
For an overview of compatible IB2 devices, see
2.2.4
V-Plex Bus for Individual I/O
V-Plex is a two-wire addressable multiplex loop that allows V-Plex sensors and
various V-Plex zone expanders to be connected and individually supervised by
the system. In addition, some V-Plex sensors have the ability to send special
signals to the control panel for special conditions, such as masking of the PIR.
Characteristics of the V-Plex bus include:
l
Provides 128 mA current on each loop.
l
Supports a maximum of 120 devices.
For V-Plex smart PIRs, you can enable the Smart Contact function. This allows
the PIR to detect a mask condition in the disarmed state.
For an overview of compatible V-Plex devices, see
2.2.5
Alarm Notification and Communication to the Alarm Receiving Center
For alarm notification, the MPI control panels provide:
l
Connections for sounders. For details, see
16
800-23044 Rev. A draft_11
Installation and Setup Guide
Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Содержание MAXPRO MPIP2000U Series