Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
Installation and Setup Guide
800-23044 Rev. A draft_11
35
# Item
Terminal
or
connector
Connect with
H Vplex BUS 1
+
V-Plex bus 1 +
–
V-Plex bus 1 –
I
IB2 BUS 1
+12V AUX1 12 VDC supply terminal for devices
connected to IB2 bus 1.
–
0 VDC supply terminal for devices connected
to IB2 bus 1.
C
IB2 bus C
D
IB2 bus D
J
IB2 bus 1
Quick connect plug for IB2 BUS 1 (can be used for
module stacked on top of main board; quick connect
cable is included).
K
LTE Cell
Radio
USB and
PWR/IO
Connectors for the 4G/LTE module
L
For future use.
M Ethernet
WAN
Network with internet connection to the
cloud.
N Relay 2
NC
Normal Closed terminal, output relay 2
C
Common terminal, output relay 2
NO
Normal Open terminal, output relay 2
Relay 2 is only available on the MPIP3000 series.
O Relay 1
NC
Normal Closed terminal, output relay 1
C
Common terminal, output relay 1
NO
Normal Open terminal, output relay 1
–
Spare 0 VDC connector.
P Triggers
For outputs. For details, see
Can also be used for a self-activating bell. For details, see
Installing a Self-Activating Bell (SAB)
Q Jumpers for low-voltage triggers. For details, see
R Zones 9, 10
For zones (sensor contact inputs). Can be used for 2-wire
smoke sensors or as standard burglary zones.
For details, see