Configuration Menu:
Allows you to take action to Pair or Purge
Nodes, Change Update Rate or Node LCD Display Time, or
Reset to WMPR to Factory Defaults. Functionality described in
Section 8.6
Receiver Detail:
Receiver information specific the WMPR
device which includes WMPR FirmWare revision, Part Number,
Radio FirmWare revision, Radio MAC ID, and Radio Transmit
Power. Functionality described in Section 8.7
6.5 | Node Detail
Figure 16. Node Detail Menu
The NODE DETAIL menu (see Figure 16) can be accessed by
touching the “Node Detail” function button as displayed in the
Action Menu (see Figure 15). Once you are in the Node Detail
menu you can choose any of the 14 node numbers by scrolling
“Up” or “Down” to the desired Node number and then touching
“Enter”. You will be able to view three screens of Node Detail
information by touching “Next” or “Prev”.
6.5.1 | Node Detail Menu, Screen 1
Figure 17. Node Detail, Screen 1
A description of the Node Detail “screen 1” information (see
Figure 17) is as follows:
Table 15. Node Display and Indication (Screen1)
Display
Indication
Not Paired
Limitless™ switch or sensor is not paired to
this Device Address location
Output:
ON
or
OFF
status for a Digital input-Limit-
less™ switch
Pressure value
and
Unit type
for Analog
sensor-Limitless™ pressure sensor
RSSI:
R
eceived
S
ignal
S
trength
I
ndication-Signal
strength between the WMPR and the Limit-
less™ switch or sensor displayed as
EXCEL-
LENT, VERY GOOD, GOOD, LOW,
or
POOR
Battery
Indicates battery condition as
OK
or
LOW
; A
LOW condition normally indicates the bat-
tery life is coming to an end and the battery
should be replaced as soon as possible.
RF Lost
RF Signal between WMPR & Limitless™
switch or sensor does not exist
6.5.2 | Node Detail Menu, Screen 2
Figure 18. Node Detail, Screen 2
A description of the Node Detail “screen 2” information (see
Figure 18) is as follows:
Table 16. Node Display and Indication (Screen 2)
Display
Indication
Rate
Update rate of Limitless™ switch or sensor
R_Lo
Low output value of a Limitless™ sensor
R_Hi
High output value of a Limitless™ sensor
S/N
Serial number of Limitless™ switch or sensor
N/A
Information not available
Not Read Yet
Information available*
*Information needs to be read from Node: Operator will need
to scroll to “Prev” or “Next” screen and then back to this
screen to allow updating of information. This action may need
to be repeated to allow time for information to be displayed.