- 15 -
5. Setting up TROUBLE input delay time
If there are TROUBLE inputs, TROUBLE output and message operate after set delay
time. Range of delay time to be set is between 1 and 99 second(s).
— When key (6) is pressed, the numeric keyboard appears. If you enter delay
time and hit ENT key, it is set up; if you enter ESC key, it is cancelled.
3.3 Display Screen for Setup of PID ZONE
There can be up to 6 ZONEs for the range of temperature PID constant
and they are controlled by the PID constants in the ZONE field in which set points (SP)
of temperature exist.
Initial setup at the time of product shipment is ZONE 1 fields and all fields are controlled
by a single PID constant.
EXIT
PID ZONE
<Figure 3.3.1>
Return to CONTROL SET screen
T1
T1
DISP
(1) Temperature ZONE
classifying constant T1
setup key
(2) Temperature ZONE
classifying constant T2
setup key
(6) ZONE range
redrawing key
(3) Temperature ZONE
classifying constant T3
setup key
1
2
3
4
5
6
T2
T3
T4
T5
= -50
T2 =
0
T3 = 50
T4 = 100
T5 = 200
(4) Temperature ZONE
classifying constant T4
setup key
(5) Temperature ZONE
classifying constant T5
setup key