47
GasAlert Extreme
Troubleshooting
Table 14. Troubleshooting Tips
Problem
Possible Cause
Solution
The detector does not display a normal
ambient gas reading after the activation
self-test.
Target gas is present
Detector is operating properly. Use caution
in suspect areas.
Detector requires calibration
Calibrate the detector. Refer to
Calibration
and Setting Alarm Setpoints
.
Sensor not stabilized
Used sensor: wait 60 seconds.
New sensor: wait 5 minutes.
The detector does not respond to the push-
buttons.
Battery is depleted
Replace the battery. Refer to
Replacing the
Battery or Sensor
.
Detector is performing operations that does
not require user input
Pushbutton operation restores automatically
when the operation ends.
The detector does not accurately measure
the gas.
Detector requires calibration
Calibrate the sensor. Refer to
Calibration
and Setting Alarm Setpoints
.
Detector is colder/hotter than ambient gas
Allow the detector to acquire ambient tem-
perature before use.
Sensor screen is blocked
Clean the sensor screen. Refer to
Cleaning
a Sensor Screen
.
The detector does not enter alarm mode.
Alarm setpoint(s) are set incorrectly
Reset the alarm setpoints. Refer to
Reset-
ting Gas Alarm Setpoints
.
Alarm setpoint(s) set to zero
Reset the alarm setpoints. Refer to
Reset-
ting Gas Alarm Setpoints
.
Detector is in calibration mode
Complete calibration. Refer to
Calibration
and Setting Alarm Setpoints
.