46
GasAlert Extreme
User Manual
Troubleshooting
If a problem occurs, refer to the solutions provided in Table 14. If the problem persists, contact
BW Technologies by Honeywell
.
Table 14. Troubleshooting Tips
Problem
Possible Cause
Solution
The detector does not activate.
No battery
Install a battery. Refer to
Replacing the Bat-
tery or Sensor
.
Depleted battery
Replace the battery. Refer to
Replacing the
Battery or Sensor
.
Damaged or defective detector
Contact
BW Technologies by Honeywell
.
Reversed battery
Reinstall the battery correctly.
The detector enters alarm mode immedi-
ately when it is activated.
Sensor needs to stabilize
Used sensor: wait 60 seconds.
New sensor: wait 5 minutes.
Low battery alarm
Replace the battery. Refer to
Replacing the
Battery or Sensor
.
Sensor alarm
Replace the sensor. Refer to
Replacing the
Battery or Sensor
.
The start up self-test fails during one of the
checks.
General fault
Contact
BW Technologies by Honeywell
.
Alarm setpoints are incorrect
Reset the alarm setpoints. Refer to
Reset-
ting Gas Alarm Setpoints
.