Table 14. Troubleshooting Tips
Problem
Possible Cause
Solution
The detector intermittently enters alarm
mode without apparent reason.
Ambient gas levels are near alarm setpoint
or the sensor is exposed to a puff of the tar-
get gas
Detector is operating normally. Use caution
in suspect areas. Check MAX gas exposure
reading.
Alarms set incorrectly.
Reset the alarm setpoints. Refer to
Calibra-
tion and Setting Alarm Setpoints
.
Missing or faulty sensor
Replace the sensor. Refer to
Replacing the
Battery or Sensor
.
The detector automatically deactivates.
Automatic shutdown feature activated due
to depleted battery
Replace the battery. Refer to <
Replacing
the Battery or Sensor
.
Detector does not auto zero or calibrate.
Sensor may be expired
Change the sensor.
O
2
sensor reading is erratic.
Sensor may be expired
Change the sensor.