107031-33-EN FR26 GLO 1101 Printed in France
43
4.
Electrical Connections
4.1
Overview
This chapter contains information about electrical installation and wiring.
IMPROPER INSTALLATION
Strictly adhere to all electrical connection instructions.
Failure to comply with these instructions could result in death or serious injury
4.2
Connector Wiring for the FF-SYA
GGGGG
GGGGG
GGGGG
GGGGG
C2 light curtains
All FF-SYA
qqqqq
C2 light curtains have two plastic quick-disconnect connectors. Emitter units and receiver units use the
same connector. The figure below illustrates a rear view of the connector (crimped contacts inserted this side). Both emitter
and receiver use the same connector type and both connectors use the same type of crimped contacts.
Figure 4-1 View of customer quick-disconnect Connector (Hirschmann N6RFF connector type)
1
2
3
4
5
6
Rear View of customer Connector
(crimped contacts inserted this side)
2
1
6
5
4
3
Front View of customer Connector
(Do NOT insert crimped contact from this side)
Ensure the following tools are available when wiring the quick-disconnect connector:
•
A set of wire strippers.
•
A flat-head screwdriver.
•
A regular crimping tool.
The crimping tool can also be ordered at Honeywell under the reference FF-SBZCRIMP. Additional crimping contacts may be
ordered under the reference FF-SBZ172115 (100 pieces)
Cross sectional area of the cables: minimum 0,5 mm² / AWG 21, maximum 1,5 mm² / AWG 16 stranded wire.
Packing Gland and recommended cable diameters to guarantee the IP 65/NEMA 4, 13 sealing: PG11 allows use of cable
diameters from 6,5 mm to 10,5 mm (0.25 in to 0.41 in)
Install socket contacts into connector as follows:
1.
Strip about 8 mm (0,3 in) of insulation from the wire end.
2.
Using a crimping tool, crimp the socket contact onto the wire.
3.
Push the socket contact into the correct slot in the connector. Tabs on the sides of the socket contact will expand into
slots and hold the socket contact in place when properly seated.
Remove a socket contact from the connector as follows:
1.
Remove the cover from the plug.
2.
Unscrew the contact receptacle.
3.
Using the removal tool, slide over socket contact and push until the spring releases the socket contact; remove socket
contact.
Change the position of the plug as follows:
1.
Unscrew the socket contact receptacle.
2.
Pull out and rotate the receptacle to change the position of the polarising slot
3.
Install the socket contact receptacle.
F
SYA6
9
F
SYA7
0