107031-33-EN FR26 GLO 1101 Printed in France
13
The cross-talk indicator is a red LED which lit on if the receiver receives two different signals from two different emitters. In this
case, the light curtain is maintained in a lock-out condition. This LED helps identify cross-talk between light curtains. For correct
operation this LED shall be off. To go back to normal operation, switch the power off and eliminate the interferences by reversing
systems emitting orientation, or by using opaque screens, or by adjusting the adequate emission power regarding the application
(see chapter
3.6
.
Mutual Interference or cross-talk
).
2.6
Specifications
OPERATING CHARACTERISTICS
Nominal Scanning Range
FF-SYA14
0 m to 6 m / 0 ft to 20 ft
FF-SYA30
0,6 m to 20 m / 2 ft to 65 ft
FF-SYA60
0,6 m to 20 m / 2 ft to 65 ft
FF-SYA02500
0,5 m to 80 m / 1.6 ft to 262.5 ft
FF-SYA03400
0,5 m to 80 m / 1.6 ft to 262.5 ft
FF-SYA04300
0,5 m to 80 m / 1.6 ft to 262.5 ft
Object Detection Size
FF-SYA14
14 mm (0.6 in) minimum (finger detection)
FF-SYA30
30 mm (1.2 in) minimum (hand detection)
FF-SYA60
60 mm (2.4 in) minimum (leg or body detection)
Beam spacing
FF-SYA02500
500 mm (19.7 in) (body detection)
FF-SYA03400
400 mm (15.76 in) (body detection)
FF-SYA04300
300 mm (11.82 in) (body detection)
Angle of Divergence
±
2
°
±
25 %
Emitting Light Source
Infrared, pulsed, 880 nm
Immunity to Ambient Light
sunlight
20 000 Lux
lamplight
15 000 Lux
ELECTRICAL CHARACTERISTICS
Supply Voltage (emitter or receiver)
24 Vdc
±
15 %, with dc to dc converter *
Power Consumption (emitter or receiver)
Emitter: 7 W maximum / Receiver: 7 W maximum
Output Type
Static safety outputs (PNP with normally open characteristic)
Output Switching Capability
0,5 A at 24 Vdc max.
Allowed loads impedance
55,2
Ω
min. / 5 k
Ω
max.
Allowed loads turn-on voltage
5 V min. on 100 % resistive loads / 7 V min. on inductive loads
Test Input
External dry contact required
Response Times
FF-SYA14
≤
22,5 ms
FF-SYA30
≤
17,5 ms
FF-SYA60
≤
17,5 ms
FF-SYA02500
≤
11,5 ms
FF-SYA03400
≤
11,5 ms
FF-SYA04300
≤
11,5 ms
Immunity to Electrical Noise
IEC 61000-4-4 (Replaces IEC 801-4 standard)
ENVIRONMENTAL/PHYSICAL CHARACTERISTICS
Operating Temperature Range
0 °C to 55
°
C (32 °F to 131
°
F)
Relative humidity
95 %
Storage Temperature Range
-20 °C to 75
°
C (-4 °F to 167
°
F)
Sealing
NEMA 4, 13, and IP 65
Housing Dimension
Width, 42 mm (1.65 in); Depth, 55 mm (2.16 in); Height**
Material
Housing
Aluminium Alloy and polycarbonate
Front Plate
Polymethylmethacrylate (PMMA)
Weight per
device
1 kg to 4,8 kg (2.20 lbs to 10.56 lbs)***
*The dc to dc converter provides immunity to external disturbances as required by the IEC/EN 61496-1 standard. This is essential to guarantee the
safety integrity of the light curtain.
**Refer to the Unit Height Table for individual unit heights.
***Refer to Emitter and Receiver dimensions / weights