44
107031-33-EN FR26 GLO 1101 Printed in France
Figure 4-2 The position of the connector can be adjusted with a 51° angular pitch
50 / 1.97
15˚
WRONG CONNECTOR HANDLING
Do NOT change the connector position when it is installed on the light curtain. The position of the connector polarising slot is
defined when assembling the connector.
Failure to comply with these instructions may result in product damage.
4.3
Connector wiring for the FF-SYA
GGGGG
GGGGG
GGGGG
GGGGG
Q2 light curtains
All the FF-SYA
qqqqq
Q2 light curtains have straight male receptacles compatible with Brad Harrison Mini-Change plugs.
The plugs can be ordered separately (see Accessories order guide section to choose the right plugs). The emitter uses a 5-
pole male receptacle and the receiver uses a 7-pole male receptacle. The figures below illustrate a front view of each male
receptacle.
Figure 4-3 View of the light curtain receptacles
(compatible with Brad Harrison Mini-Change plugs)
5
3
1
4
2
7
1
6
4
2
5
3
Face view of the emitter receptacle
(7/8 in – 16 UNS – 2 A thread
Face view of the receiver receptacle
(1 in – 16 UN – 2 A thread)
4.4
Terminal strip wiring for the FF-SYA
GGGGG
GGGGG
GGGGG
GGGGG
T2 light curtains
The FF-SYA
qqqqq
T2 light curtain models are equipped with terminal strips. Both emitter and receiver include the same
PG13 cable glands on delivery. The FF-SYA emitters and receivers are wired using internal terminal strips located behind the
end caps.
Ensure the following tools are available:
•
A flat-head and a crosspoint screwdriver.
•
A stripping pliers
Cross sectional area of the cables: minimum 0,5 mm² / AWG 21, maximum 1,5 mm² / AWG 16 stranded wire.
Packing Gland and recommended cable diameters to guarantee the IP 65/NEMA 4, 13 sealing: PG13 allows use of cable
diameters from 8 mm to 13 mm (0.32 in to 0.51 in)
Remove end cap and wire the terminal strips as follows:
1.
Unscrew and take off the end cap with the cable gland mounted.
2.
Unplug the plugged in terminal strip using the Nylon
®
twine fixed to the terminal strip.
3.
Insert the cable into the cable gland.
4.
Strip about 7 mm (0,28 in) of insulation from the lead wire end.
F
SYA7
1
F
SYA7
2
F
SYA7
3