IMPROPER PERIMETER PROTECTION ACTIVATION
•
Design control circuit that requires a manual restart before further machine operation can occur.
•
Locate manual restart to allow operator a clear view of danger zone.
•
Operator must NOT be able to reach manual restart from within danger zone.
•
Design control circuit to prevent Programmable Logic Controller from overriding manual restart.
Failure to comply with these instructions could result in death or serious injury.
2.3
Approval and rating plates
Figure 2-4 Rating plate of the FF-SYA14, FF-SYA30 and FF-SYA60 Series light curtains
Figure 2-5 Rating plate of the FF-SYA234 multibeam systems for access detection
NSR
Nominal Scanning Range
I
Output Switching Capacity
PH
Protection Height
Type
Product Part Number
N
Number of beams
N°
Serial number
R
Resolution
Date
Date code (month/year)
BS
Beam spacing
S
Sealing
V
Supply Voltage (power consumption)
L
Loads specifications (max. impedance and min; turn-on
voltage)
T
Response time
Service
Sales and Service phone numbers