Maintenance and Troubleshooting
5.1
Overview
This chapter contains operational test procedures, troubleshooting, cleaning, and maintenance, instructions.
IMPROPER MAINTENANCE
Strictly adhere to all maintenance and troubleshooting instructions.
Failure to comply with these instructions could result in death or serious injury.
5.2
Operational Test
To ensure operational readiness, perform the operational test at least once a day and every time the light curtain is
repaired or the installation is changed. The operational test consists of passing a test rod (included with the FF-SYA14
or FF-SYA30 units) or the hand (for the FF-SYA60 units or the FF-SYA234 multibeam systems) through the sensing
field to ensure the light curtain will detect it (see
Figure 5-1
). The sensing function of the light curtain shall be actuated
by moving the relevant test rod at a maximum speed of 2,5 m/s for the FF-SYA14 and the FF-SYA30 (or by moving the
hand at a maximum speed of 1,6 m/s for the FF-SYA60 and the FF-SYA234). The included test rod will have a
diameter equal to the resolution of the light curtain.
Light Curtain
Resolution
FF-SYA14
14 mm / 0.6 in
FF-SYA30
30 mm / 1.2 in
FF-SYA60
60 mm / 2.4 in
FF-SYA234 Multibeam System
Beam Spacing
FF-SYA02500
500 mm / 19,7 in
FF-SYA03400
400 mm / 15,76 in
FF-SYA04300
300 mm / 11,82 in
Figure 5-1 Operational Test with the Test Rod