7810iR Internet Communication Module Installation and Setup Guide
4-4
Action Screen
Display
4. Check
Use Master Account #
doughnut
only if the Master Account number is to be
used as the AlarmNet account. Otherwise,
touch each data field and enter the required
account information.
NOTE:
If the
Master Account#
doughnut
is checked, the
Primary Account
information is automatically filled in with the
Master Account Number information. This
information is displayed in gray and cannot
be edited as long as the
Master Account #
doughnut is checked.
5. Use the data entry keypad to enter
required account information.
6. Check
Enable Second CS
to report this
7810iR power-on reset and test messages
to a second CS. Enter the required account
information by touching each field.
Select
Options
tab.
7.
Old Alarm Time
on 7810iR is only
applicable for power-on reset messages
and test messages.
Fault Time Minutes
is
not supported by the
7810iR.
Account Supervision s
ets the AlarmNet
supervision period.
UL
For UL installations,
US UL
Line Sec Account
Supervision
must be
selected.
C-UL
For C-UL installations,
CN
UL Line Sec Account
Supervision
must be
selected.
Содержание AlarmNet 7810iR
Страница 2: ......
Страница 6: ...7810iR Internet Communication Module Installation and Setup Guide 1 2 ...
Страница 12: ...7810iR Internet Communication Module Installation and Setup Guide 2 6 ...
Страница 16: ...7810iR Internet Communication Module Installation and Setup Guide 3 4 ...
Страница 62: ...7810iR Internet Communication Module Installation and Setup Guide 7 10 ...