Homa H500 B Скачать руководство пользователя страница 9

 

Index of contents 

 

Contents Page 

  1.    EC Declaration of Conformity 

  2.    Safety Warnings 

10 

  2.1. General instructions 

10 

  2.2. General Safety Warnings 

10 

  3.    Applications and Technical 
         Description 

10 

  3.1. Applications 

10 

  3.2. Technical Data 

10 

  3.3. Operation Conditions 

10 

  3.4. Explosive Environments 

10 

  4.    Warranty 

10 

  5.    Transport and Storage 

11 

  6.    Electrical Connection 

11 

  6.1. Connection of 1Ph-Motors 

11 

  6.2. Connection of 3Ph-Motors 

11 

  6.3. Temperature Sensors 

11 

  6.4. Check of Direction of Rotation 

11 

  7.    Installation 

11 

  7.1. Submerged Installation 

11 

  7.2. Automatic Float switch Control 

11 

  8.    Start-Up 

12 

  9.    Maintenance and Repair 

12 

10.    Fault Finding Chart 

13 

11.    Warranty Conditions and Warranty 
         Receipt 

13 

13.    Wiring Diagrams 

19 

14.    Dimensions 

19 

15.    Order Sheet for Spare Parts 

21 

16.    Spare Part Lists and Drawings 

23 

16.1. Spare part list 

23 

16.2. Spare part drawings 

24 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1. Declaration of Conformity 

 

EC Declaration of conformity in line with the EC Ma-
chinery Directive 89/392/EEC, Appendix II A 
 
We, HOMA Pumpenfabrik GmbH, Industriestrasse 1,  
D-53819 Neunkirchen-Seelscheid, hereby declare that in 
respect to their design and construction the following 
pump types, in the form in which they are marketed by us, 
conform to the relevant fundamental safety and health 
requirements of the EC Machine Directives: 
H 500... 

H 700... 

 

 

Any modification of any pump not agreed with us shall 
cause this declaration to lose its validity. 
 
EC-Directives to which the pumps conform: 
EC Machinery Directive 

98/  37/EEC 

EC Directive, electromagnetic 
compatibility 

89/336/EEC  

as amended 

92/  31/EEC  

as amended 

93/  68/EEC  

EC Low Voltage Directive 

1)

 

73/  23/EEC  

EC Directive, explosion-
prooved operating material 

2)

 

94/    9/EEC 

EC Directive, construction 
products 

89/106/EEC 

 
Relevant harmonized industrial standards: 
ES 60335-2-41

1)

 ES 

60335-1

1)

 

ES 60034 Part 5 

ES 60204 Part 1

1)

  ES 61000-6-1  ES 61000-6-2 

ES 61000-6-3 

ES 61000-6-4  ES 55014-1 

ES 55014-2 

ES 61000-3-2  ES 61000-3-3 

ES 12050 1-4 

ES 292 

ES 50014/18/19/20

2)

 

 
Specially applied national standards and technical 
specifications (other applied standards for general 
mechanical engineering are deposited at the con-
struction office):
 
ISO 9906 

DIN 24250 

 
 
 
 
 
 

(Dr. Klaus Hoffmann, 

Management) 

01.06.2004 

HOMA Pumpenfabrik GmbH 

 
 

1)

 does not apply to Ex models 

2)

 only applies to Ex models 

 
 
 
 
 
 

Established:     Totzke  Index: 

            0 

Date: 

01.06.2004  Current number:     CE  1

 

 

Содержание H500 B

Страница 1: ...Montage und Bedienungsanleitung Installation and Operation Instruction Manual Montage en Bedrijfsinstrukties 01 2005 Baureihe Series Serie H500 H700...

Страница 2: ...Pagina 19 Seite 22 Page 22 Pagina 23 DEUTSCH ENGLISH NEDERLANDS Elektroanschluss Electrical connection Elektrische aansluitingen Bauma e Dimensions Afmetingen Ersatzteilliste und Ersatzteilzeichnunge...

Страница 3: ...ass die Pumpentypen H500 H700 aufgrund Ihrer Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderun gen der...

Страница 4: ...Wir weisen darauf hin dass wir nach dem Produkthaf tungsgesetz f r Sch den die durch unser Ger t verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten...

Страница 5: ...altger t mit Motorschutzschalter Weitere HOMA Schaltger te sind als Zubeh r lieferbar s Schaltger te Programm Bei Verwendung anderer Schaltger te ist bei der Auslegung des Motorschutzschalters auf den...

Страница 6: ...u kontrol lieren 8 Inbetriebnahme Die Pumpe niemals l ngere Zeit trocken laufen las sen berhitzungsgefahr Die Pumpe muss v llig im F rdermedium eingetaucht und entl ftet sein Absperrventile ffnen Fall...

Страница 7: ...lung Kabel und Motor von einem Elektriker berpr fen und aus bessern lassen sofort aus Achtung Nicht wieder einschal ten Sicherung durchge brannt da falscher Typ Sicherung durch korrekten Typ erset zen...

Страница 8: ...f Renner Stra e 76 Akazienweg 16 01796 Pirna 68809 Neulussheim 0 35 01 52 34 48 0 62 05 3 11 12 PAW Pumpen Aggregate GbR Giese Pumpentechnik Kleine Basch tzer Str 3 Belsemer Steg 14 02625 Bautzen 7213...

Страница 9: ...clare that in respect to their design and construction the following pump types in the form in which they are marketed by us conform to the relevant fundamental safety and health requirements of the E...

Страница 10: ...y law we point out that we shall not be liable for damages caused by the pump due to non observance of the instructions and guidelines set forth in the operating instructions The same product liabilit...

Страница 11: ...1 L2 L3 through the motor starter according to fig 1 Page 20 6 3 Temperature Sensors Pump types with a motor input above 5 5 kW have a set of temperature sensors built in the stator windings The conta...

Страница 12: ...r by persons other than the manufacturer or an authorized workshop or due to the use of spare parts other than original HOMA parts The same product liability limitations are valid for accessories Befo...

Страница 13: ...only by presentation of the fill in warranty receipt together with the purchase receipt Our warranty extends only the removal of material defects or production defects Costs for removal and installati...

Страница 14: ...rasse 1 D 53819 Neunkirchen Seelscheid verklaren hiermee dat de pomp typen H 500 H 700 Op grond van hun concipi ring en bouwwijze als ook in de door ons in verkeer gebrachte uitvoering aan de des betr...

Страница 15: ...ook de de algemeen erkende regels der techniek dienen in acht ge nomen te worden Wij wijzen erop dat wij volgens de product aansprakelijk heidswet niet aansprakelijk zijn voor schade welke door onze...

Страница 16: ...akelaar de nennstroom van de pompmotor in acht te nemen zie typeplaatje Start wijze De pompen zijn voor Direkt Start DOL geconstrueerd Bij de motoren met 400 V zijn de wikkelingen in Ster geschakeld v...

Страница 17: ...tisch in of uitgeschakeld Voor een uitvoering zonder niveauschakelaar de keuzeschakelaar van de schakelkast in de Hand stand zetten Nadat de pomp de vloeistof heeft weggepompt de keuze schakelaar weer...

Страница 18: ...uitbouwkosten van de voor garantie in aanmerking komende machine op de bedrijfslocatie reiskosten van het repa ratiepersoneel van en naar de bedrijfslocatie als mede transport kosten zijn geen bestan...

Страница 19: ...3 5 D 220 600 120 230 1 10 R 2 AG BSP 2 M 5 5 D 250 650 138 250 1 10 R 4 AG BSP 4 M 7 5 D 280 780 126 370 2 15 R 4 AG BSP 4 M 10 D 280 780 126 3702 15 R 6 AG BSP 6 M 10 HD 280 780 126 370 2 15 R 3 IG...

Страница 20: ...Nr Bezeichnung Menge Lieferanschrift Unterschrift Firmenstempel 15 Order Sheet for Spare Parts To HOMA Pumpenfabrik GmbH D 53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Ye...

Страница 21: ...efoon 0183 622212 Fax 0183 620193 Pompentype Typeplaatje Bouwjaar Typeplaatje Gedetailleerde onderdelenlijst 1 Pos Nr Beschrijving Aantal 2 Pos Nr Beschrijving Aantal 3 Pos Nr Beschrijving Aantal 4 Po...

Страница 22: ...n 940 Pa feder 704 Rohrnippel Zulaufrohr f r umflutete Motoren 950 Kugellager Ausgleichsscheibe 719 Schrumpfschlauch 970 Typenschild 720 Anschlusswinkel 90 990 xx Motor l 721 STA Schlauch Verschraubun...

Страница 23: ...tingsring bijv 411 01 02 voor olie plug 411 03 837 Bedrijfscondensator 412xx O ring 838 Schakelkast 420 Keerring 838 09 Startrelais 420 01 Keerring onderste 838 45 Niveauschakelaar 420 02 Keerring bov...

Страница 24: ...24 H 500 B 7 5 D 10 H D H 700 B 2 5 D 3 5 D H 500 B 5 5 D H 700 B 7 5 10 D...

Отзывы: