OPERATION
30
WP20ECO | WP30ECO
Unscrew the transport seal screw (12b) and screw in
the manometer (8).
Pull off cap (12c) and screw in hydraulic hose (11b).
NOTE:
Absolute cleanliness must be ensured during
assembly!
Mount the working table (3) on the machine.
To do this, push both bed frame pins (13 x 2) into the
posts and place the working table (3) onto.
Secure with circlips (15 x 4)).
Place the workpiece support (14) onto the worktable.
Insert the handle (9).
Check and tighten all screw connections
WP20ECO
WP30ECO
OPERATION
Only operate the machine when it is in a perfect condition. Before each operation, a visual
inspection of the machine must be carried out. Safety devices, hydraulic hoses, compressed air
hoses and operating elements, must be checked carefully. Check screw connections for damage
and tight fit.
N OTE
Check compressed air connection and, if necessary, adapt to the compressed air
supply line used.
15.1
Before first use
Before first use of this machine it is necessary to bleed the hydraulic system: