42
Error Codes
geodyna optima
Operator’s Manual
E393
Rear scanner not calibrated
Possible causes:
•
the rear scanner has not been factory calibrated
Corrective actions:
•
please call service and replace the rear
scanner.
E394
Rear motor current sink or power supply failure
Possible causes:
•
the cable connecting the camera controller
board and the rear scanner motor is unplugged,
damaged or missing
•
the motor power supply is not configured
properly
•
there is a fault in the motor power supply board
•
the cable connecting the mains supply and the
motor power supply board is unplugged,
damaged or missing
•
there is a fault in the rear scanner motor
•
there is a fault in the camera controller board
motor drivers
Corrective actions:
•
check all items above.
E395
Rear scanner zero mark not detected
Possible causes:
•
the flat cable connecting the camera controller
board and the rear scanner CCD board is
unplugged, missing or damaged
•
there is a fault in the rear scanner CCD board
•
the rear scanner is locked
•
the rear scanner zero mark is missing, bent,
locked or damaged
•
the cable connecting the camera controller
board and the rear scanner motor is unplugged,
damaged or missing
•
there is a fault in the motor power supply board
•
there is a fault in the rear scanner motor
•
there is a fault in the camera controller board
motor drivers
Corrective actions:
•
check all items above.
Содержание geodyna optima
Страница 1: ...geodyna optima Additional instructions Wheel balancer ...
Страница 2: ......
Страница 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Страница 56: ...54 Electrical diagram ...
Страница 57: ...55 Electrical diagram ...
Страница 58: ...56 Electrical diagram ...
Страница 59: ...57 Electrical diagram ...
Страница 61: ...Note page ...