35
•
the cable connecting the camera controller
board and the encoder board is unplugged,
missing or damaged
Corrective actions:
•
check the camera controller board
•
check the encoder
•
check the connections.
E370
Inner CCD signals failure
Possible causes:
•
the flat cable connecting the camera controller
board and the inner scanner CCD board is
unplugged, missing or damaged
•
there is a fault in the inner scanner CCD board
•
there is a fault in the camera controller board
•
the supply voltage is configured too high on
the power interface board
Corrective actions:
•
check all items above
•
switch power off and on again; should the
problem not go away please call service.
E371
Inner scanner memory not responding
Possible causes:
•
the flat cable connecting the camera controller
board and the inner scanner CCD board is
unplugged, missing or damaged
•
there is a fault in the inner scanner CCD board
•
there is a fault in the camera controller board
Corrective actions:
•
check the connections
•
check the inner scanner CCD board
•
check the camera controller board
•
switch power off and on again; should the
problem not go away please call service.
E372
Inner scanner memory not valid
Possible causes:
•
the flat cable connecting the camera controller
board and the inner scanner CCD board is
partially unplugged or damaged
•
there is a fault in the inner scanner CCD board
Corrective actions:
•
check the connections
Содержание geodyna optima
Страница 1: ...geodyna optima Additional instructions Wheel balancer ...
Страница 2: ......
Страница 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Страница 56: ...54 Electrical diagram ...
Страница 57: ...55 Electrical diagram ...
Страница 58: ...56 Electrical diagram ...
Страница 59: ...57 Electrical diagram ...
Страница 61: ...Note page ...