40
Error Codes
geodyna optima
Operator’s Manual
E386
Outer motor missing steps
Possible causes:
•
the outer scanner movement is not smooth or
it is striking the frame
•
the motor power supply is not configured
properly
•
there is a fault in the motor power supply board
•
there is a fault in the outer scanner motor
•
there is a fault in the camera controller board
motor drivers
•
the cable connecting the camera controller
board and the outer scanner motor is partially
unplugged or damaged
Corrective actions:
•
check all items above.
E387
Outer laser current sink or power supply failure
Possible causes:
•
the flat cable connecting the camera controller
board and the outer scanner CCD board is
unplugged, missing or damaged
•
the cable of the laser module of the outer
scanner is damaged or there is a fault in the
laser module itself
•
there is a fault in the camera controller board
laser drivers
Corrective actions:
•
check all items above.
E388
Outer laser modulation failure
Possible causes:
•
the flat cable connecting the camera controller
board and the outer scanner CCD board is
unplugged, missing or damaged
•
the cable of the laser module of the outer
scanner is damaged or there is a fault in the
laser module itself
•
there is a fault in the camera controller board
laser drivers
Corrective actions:
•
check all items above.
Содержание geodyna optima
Страница 1: ...geodyna optima Additional instructions Wheel balancer ...
Страница 2: ......
Страница 55: ...53 geodyna optima Operator s Manual Manuel d Utilisation Note Note page La página de la nota ...
Страница 56: ...54 Electrical diagram ...
Страница 57: ...55 Electrical diagram ...
Страница 58: ...56 Electrical diagram ...
Страница 59: ...57 Electrical diagram ...
Страница 61: ...Note page ...