Copyright IXXAT Automation GmbH
UCI Programming Manual FlexRay, V1.13
External interfaces
41
WORD wLastStaticSlotId
ID of the last static slot.
WORD wLastDynamicSlo-
tId
ID of the last dynamic slot.
Remark:
This ID is only valid if no other
dynamic messages are on the bus in one
cycle.
WORD wStaticDataLength Data length in [WORDS] for all static mes-
sages.
WORD wMaxDynamic-
DataLength
Maximum data length in [WORDS] of a
dynamic message.
DWORD dwBaudrate
Baudrate in [BAUD].
DWORD dwCycleLength
Length of one cycle in [ns].
DWORD dwStaticSlotLength Length of one static slot in [ns].
WORD wMacrotickLength Length of one Macrotick in [ns].
WORD wMicrotickLength Length of one Microtick in [ns].
char
szBoardManu-
facturer[24]
Zero terminated string of board manu-
facturer.
char
szChipManu-
facturer[24]
Zero terminated string of chip manu-
facturer.
char
szBoardName[24] Zero terminated string of board name.
For szBoardName definitions please take a
look in “UciFlx.h”
UCI_FLXINFO_BOARD_NAME…
Some information is only available in initialized – mode (after
was called).
•
dwInitInfoFlags
•
wLastStaticSlotId
•
wLastDynamicSlotId
•
wStaticDataLength
•
wMaxDynamicDataLength
•
dwBaudrate
•
dwCycleLength
•
dwStaticSlotLength
•
wMacrotickLength
•
wMicrotickLength
Содержание FlexRay CCM