Copyright IXXAT Automation GmbH
UCI Programming Manual FlexRay, V1.13
External interfaces
53
DWORD dwCurrentSettings
Flag field of current settings of the
transmit message / buffer.
bit 0..5
0x003f
UCI_FLXTXMSGINFO_
CURSET_
CYCLEFILTERVALUE
Cycle counter filter value
(0-63 {6 bit})
bit 6
0x0040
UCI_FLXTXMSGINFO_
CURSET_
CYCLEFILTERENABLE
Cycle counter filter enabled.
Remark:
Transmission of the message
will only occur if the filter settings are
met. The communication controller
will first check the cycle the user has
requested and afterwards the cycle
filter settings
bit 7
0x0080
UCI_FLXTXMSGINFO_
CURSET_
CYCLICTRANSMIT
ENABLE
Cyclic transmission enabled.
Remark:
If cyclic transmission is
enabled the transmission will go on
(with same data) until the communi-
cation controller is stopped. Data can
be changed by sending a new mes-
sage. (
MFR43x0 only!
bit 8..13
0x3f00
)
UCI_FLXTXMSGINFO_
CURSET_
CYCLEFILTERMASK
Cycle counter filter mask
(0-0x3F {6 bit})
bit 14
0x4000
UCI_FLXTXMSGINFO_
CURSET_DISABLED
TX buffer disabled
Remark:
If set no transmission is al-
lowed. The state can be controlled
with
bit 15
0x8000
UCI_FLXTXMSGINFO_
CURSET_TXPENDING
Transmission pending:
Remark:
If set a transmission is cur-
rently pending. This can occur if a cyc-
lic transmission is in progress, a dy-
namic ID should be transmitted, but
the dynamic segment ends before
correct Minislot is reached or the TX
queue has pending messages. A
pending transmission can be aborted
with
bit 16..31 Reserved
Reserved for future use.
Содержание FlexRay CCM
Страница 6: ......