Copyright IXXAT Automation GmbH
UCI Programming Manual FlexRay, V1.13
Overview
9
The user first creates an instance of the UCI, which is equivalent to opening the
board. For this he calls the function
exported from the
UCI. This function returns a pointer to the COM interface
specific information on the IXXAT FlexRay interface can be called
up and controllers selectively opened. In turn, by opening a controller, a pointer
to the relevant controller COM interface is requested.
provides the access to the FlexRay controller. The controller is initia-
lized with certain operating modes and the hardware-specific communication
parameters are set. Furthermore, accesses to receive or transmit streams and en-
quiries of controller and bus states are carried out via the controller interface.
Содержание FlexRay CCM