3.2.2 XEG-C2
Code
Part Name
Illustration
PWR
24V Power supply lamp (Green)
Lights after 24V / 0V power input
ALM
Error status lamp (Red)
Lights after error status occurs [Note 1]
USB
5V Power supply lamp (Green)
Lights after USB cable is connected
EMG
Emergency stop lamp (Red)
Lights after emergency stop trigger
CN1
Power terminal and Emergency
stop terminal
Connect power supply and emergency stop [Note 2]
CN2
Actuator terminal
Connect actuator cable
CN3
Communication terminal
Connect USB cable
CN4
Communication terminal
Connect RS485 cable [Note 3]
CN5
Communication terminal
Connect RS485 cable [Note 3]
CN6
I/O signal terminal
Connect I/O cable
CN7
Station channel
Set controller station number [Note 4]
CN8
Terminal resistor
Two-stage switch, left direction is off, right direction
is on [Note 5]
[Note 1] The display mode of the ALM indicator in each abnormal state is as follows:
[Note 2] The description and wiring diagram of the power connector are as follows. When EMG + and EMG- are
disconnected, the emergency stop function is activated (Servo off) , and the electric gripper stops immediately.
[Note 3] The pin definition of the RS485 cable is as follows. Please use EIA-485 as the reference, use twisted pair
cables and recommend TIA/EIA CAT5e or more. A maximum of 15 controllers can be connected in series, and
the longest serial cable length is 50 meters in total.
Error Status
ALM Indicator
1. Position fault
After every 1 second, ALM indicator blinks 1 time
2. Over travel
After every 1 second, ALM indicator blinks 2 times
3. Original point fault
After every 1 second, ALM indicator blinks 3 times
4. Trigger emergency stop
After every 1 second, ALM indicator blinks 4 times
5. Firmware version update
Continuous flashing
PIN
Define
Color
1
N/A
White/Orange
2
GND
Orange
3
D+
White/Green
4
N/A
Blue
5
GND
White/Blue
6
D-
Green
7
N/A
White/Brown
8
N/A
Brown
1 2 3 4 5 6 7 8
C02UE03-2007
15