![Hitachi SJ2002 Series Скачать руководство пользователя страница 267](http://html.mh-extra.com/html/hitachi/sj2002-series/sj2002-series_instruction-manual_142353267.webp)
SJ200
2
Inverter
Appendix B
B–29
A054
DC braking force for
deceleration
R/W Level of DC braking force,
settable from 0 to 100%
1054h
04180
0 to 100
1 %
A055
DC braking time for
deceleration
R/W Sets the duration for DC
braking, range is 0.0 to 60.0
seconds
1055h
04181
0 to 600
0.1 sec
A056
DC braking / edge or
level detection for [DB]
input
R/W Two options; select codes:
00 ...Edge detection
01 ...Level detection
1056h
04182
0, 1
—
A061
Frequency upper limit
setting
R/W Sets a limit on output
frequency less than the
maximum frequency (A004).
Range is from frequency
lower limit (A062) to
maximum frequency (A004).
0.0 ..setting is disabled
>0.1 setting is enabled
105Ah 04186
(A062 x
10) to
(A004 x
10),
0=disable
>1=enabl
e
0.1 Hz
A261
Frequency upper limit
setting, 2nd motor
R/W
1517h
05399
A062
Frequency lower limit
setting
R/W Sets a limit on output
frequency greater than zero.
Range is start frequency
(B082) to frequency upper
limit (A061).
0.0 ..setting is disabled
>0.1 setting is enabled
105Bh 04187
(B082 x
10) to
(A061 x
10),
0=disable
>1=enabl
e
0.1 Hz
A262
Frequency lower limit
setting, 2nd motor
R/W
1518h
05400
A063,
A065,
A067
Jump (center) frequency
setting
R/W Up to 3 output frequencies
can be defined for the output
to jump past to avoid motor
resonances (center frequency)
Range is 0.0 to 400.0 Hz
105Dh
1060h
1063h
04189
04192
04195
0 to 4000
0.1 Hz
A064,
A066,
A068
Jump (hysteresis)
frequency width setting
R/W Defines the distance from the
center frequency at which the
jump around occurs
Range is 0.0 to 10.0 Hz
105Eh
1061h
1064h
04190
04193
04196
0 to 100
0.1 Hz
A071
PID Enable
R/W Enables PID function,
two option codes:
00 ...PID Disable
01 ...PID Enable
1068h
04200
0, 1
—
A072
PID proportional gain
R/W Proportional gain has a range
of 0.2 to 5.0
1069h
04201
2 to 50
0.1
A073
PID integral time
constant
R/W Integral time constant has a
range of 0.0 to 150 seconds
106Ah 04202
0 to 1500
0.1 sec
A074
PID derivative time
constant
R/W Derivative time constant has a
range of 0.0 to 100 seconds
106Bh 04203
0 to 1000
0.1 sec
Holding Registers for “A” Group Standard Functions
Func.
Code
Name
R/W
Description
Network Data
Register
Range
Res.
hex
dec.
Содержание SJ2002 Series
Страница 2: ......
Страница 46: ......
Страница 203: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 214: ......
Страница 231: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 282: ......
Страница 283: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 295: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 D ...
Страница 299: ...SJ2002 Inverter Appendix D D 5 L1 L2 L3 PE SJ2002 inverter with book type filter M 3 ...