Trip History and Inverter Status
We recommend that you first find the cause of the fault before clearing it. When a fault
occurs, the inverter stores important performance data at the moment of the fault. To
access the data, use the monitor functions (Dxxx) and select D081 for details about the
present fault (E
n
). The previous two faults are stored in D082 and D083, with D(E
n-1
and
E
n-2
). Each error shifts D081–D082 to D082–D083, and writes the new error to D081.
The following Monitor Menu map shows how to access the error codes. When fault(s)
exist, you can review their details by first selecting the proper function: D081 is the most
recent, and D083 is the oldest.
2
1
Error Code
Output frequency
at trip point
Motor current
at trip point
DC bus voltage
at trip point
No error
Yes
No
2
1
2
2
d
0 8 1
d
0 8 3
d
0 8 2
28 4.0
Monitor Menu
Trip
Conditions
Error
exists?
2
1
2
1
2
1
1 5
2
1
2
1
1 8
2
1
Cumulative inverter
operation time at
trip point
Cumulative power-
ON time at trip point
FUNC.
FUNC.
FUNC.
2.5
1 0.0
E 0 9
Содержание SJ2002 Series
Страница 2: ......
Страница 46: ......
Страница 203: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 214: ......
Страница 231: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 282: ......
Страница 283: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 295: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 D ...
Страница 299: ...SJ2002 Inverter Appendix D D 5 L1 L2 L3 PE SJ2002 inverter with book type filter M 3 ...