Using Intelligent Input Terminals
Oper
ations
and Monitor
ing
4–24
Analog Input Current/Voltage Select
The [AT] terminal selects whether the inverter uses the voltage [O] or current [OI] input
terminals for external frequency control. When intelligent input [AT] is ON, you can set
the output frequency by applying a current input signal at [OI]-[L]. When the [AT] input
is OFF, you can apply a voltage input signal at [O]-[L] to set the output frequency. Note
that you must also set parameter A001 = 01 to enable the analog terminal set for control-
ling the inverter frequency.
Option
Code
Terminal
Symbol
Function Name
Input
State
Description
16
AT
Analog Input
Voltage/current
Select
ON
Terminal OI is enabled for current input (uses
terminal L for power supply return)
OFF
Terminal O is enabled for voltage input (uses
terminal L for power supply return)
Valid for inputs:
C001, C002, C003, C004,
C005, C006
Required settings:
A001 = 01
Notes:
•
If the [AT] option is not assigned to any intelligent
input terminal, then inverter uses the algebraic sum
of both the voltage and current inputs for the
frequency command (and A001=01).
•
When using either the analog current and voltage
input terminal, make sure that the [AT] function is
allocated to an intelligent input terminal.
•
Be sure to set the frequency source setting
A001=01 to select the analog input terminals.
+ –
4-20 mA when AT= ON
0-10 V when AT= OFF
1
2
3
4
5
6
L
PCS
12 11
L
H O OI
FM CM2
Example (default input configuration shown
for –FU models; –FE and –FR models require
input configuration—see page
3–45
):
See I/O specs on page
4–6
.
AT
Содержание SJ2002 Series
Страница 2: ......
Страница 46: ......
Страница 203: ...Inverter System Accessories In This Chapter page Introduction 2 Component Descriptions 3 Dynamic Braking 5 5 ...
Страница 214: ......
Страница 231: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Страница 282: ......
Страница 283: ...Drive Parameter Settings Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...
Страница 295: ...CE EMC Installation Guidelines In This Appendix page CE EMC Installation Guidelines 2 Hitachi EMC Recommendations 6 D ...
Страница 299: ...SJ2002 Inverter Appendix D D 5 L1 L2 L3 PE SJ2002 inverter with book type filter M 3 ...