17
Tab. 8 The contents of Option mode
No.
Item
Content
Setting range
Default
1 Language
Setting language.
If the language is not installed, it is
displayed in English.
(NOTE1)
01: English
02: Deutsch (German)
03: Français (French)
04: Español (Spanish)
05: Italiano (Italian)
06: Portuguës(Portuguese)
07:
日本語
(Japanese )
08:
中文
(Chinese)
09: Türkçe (Turkish)
10:
Р
ycck
ий
(Russian)
(NOTE 1)
English
2
Date and Time
Setting date and time.
Day of the week is changed
automatically with the date.
(NOTE2)
format
:
1
date:
2009/01/01~2099/12/31
time: 00:00 ~ 23:59
format
:
2
date:
01/01/2009~12/31/2099
time: 00:00 ~ 23:59
format
:
3
date:
01/01/2009~31/12/2099
time: 00:00 ~ 23:59
2009/01/01
00:00
format 1
3 Read
Lock
Protect the parameter in WOP that
has been saved from being
overwritten. If the state of Read Lock
is [01:Enable], READ operation is
impossible. (NOTE3)
01: Enable
02: Disable
Disable
4
INV Type Select
Selecting the correct inverter type.
”COM ERROR” will be displayed if
the incorrect inverter type was
selected.
01: Type 1
(WJ200: Ver.2.0 or above,
NE-S1
)
(NOTE4)
02: Type 2
(L700, SJ700, X200)
Type 1
5
R/W Storage
Mode
Reflecting the quantity of setting of
parameter sets that can be stored in
WOP.
(Refer to chapter 5 for more details.)
01: Single
02: Quad
02
6
Backlight
Auto-Off
LCD backlight will be turned off
automatically if there was no
operation within 1 minute.
The Backlight Auto-Off function does
not work when trip happens.
01: Off
02: 1 minute
Off
7 Backlight
Flicker
Setting the flicker state (Yes/No) of
orange backlight.
If [02:Disable] is selected, the orange
backlight won’t flicker in the case of
trip status.
01: Enable
02: Disable
Enable
Chapter 4
Operation