8
SRW-OJ (the same as SRW-OEX)
WOP
2.5
Connect to SJ700,L700,X200 and WJ200 (before Version 2.0)
Display contents and operation system of WOP are different according to the inverter type
that is connected to. When WOP is connected to SJ700, L700, X200 and WJ200 (before
Version 2.0), it displays in the same way of former remote operators such as SRW-OJ and
SRW-OEX. Otherwise, the differences of LED and functions of key are described in Tab. 6.
Tab. 6 Differences between former inverter
KEY & LED of WOP
W
J200 (Ver.2.0 or above), NE-S1
L700, SJ700, X200
REMOTE (Long push)
Compulsion operation function effective / invalid
REMOTE (Short push)
(No response because of absence
of the function)
Move to monitor mode
(
Monitor/MON key
)
READ
Reading of parameter
Reading of parameter
(
Read/READ key
)
WRITE
Writing of parameter
Writing of parameter
(
Copy/COPY key
)
ESC
Back to the upper layer
Move to function mode
(
Function/FUN key
)
SET
Store the setting value / Enter the
lower layer
Store the setting value
(
Store/STR key
)
POWER LED
Power on
RUN LED
Inverter is running
WARNING LED
Warning happened
(
LED always turns off because of
absence of the function
)
ALARM LED
Inverter trip happened
OPE LED
The compulsion operation function is effective by the operator
KEY ENABLED LED
Operation command key is effective
FM 0000.00Hz
>F001 0010.00Hz
Fig. 3 Comparison of WOP and SRW-OJ/SRW-OEX
FM 0000.00Hz
>F001 0010.00Hz
RM=MON ESC=FUN SET=STR
Chapter 2
Name of parts and functions of WOP
○
REMOTE OPERATOR
○
○
○
○
○